Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwY1731TestIdTwoDelayStatTable

hwY1731TestIdTwoDelayStatTable

This table is used to display statistics about Y.1731 two-way frame delay measurement in real time.

The indexes of this table are hwY1731TestIdentifier and hwY1731TestIdTwoDelaySequence.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.136.1.8.2.10.1.1

hwY1731TestIdTwoDelaySequence

Unsigned32

Read-only

This object indicates the sequence number of statistics data. The value is equal to a timestamp, in ms. After the sequence number reaches 0xFFFFFFFF, the next sequence number starts from 0.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.8.2.10.1.2

hwY1731TestIdTwoDelayErrInfo

Unsigned32

Read-only

This object indicates error information about two-way frame delay measurement.

This object is implemented as defined in the corresponding MIB file. The current version does not support this object.

1.3.6.1.4.1.2011.5.25.136.1.8.2.10.1.3

hwY1731TestIdTwoDelay

Unsigned32

Read-only

This object indicates the two-way delay time, in us.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.8.2.10.1.4

hwY1731TestIdTwoDelayVariation

Unsigned32

Read-only

This object indicates the two-way variation time, in us. An absolute value is used.

After two-way frame delay measurement is enabled, the first group of delay data received does not contain a delay variation time. The delay variation time in this group of delay data is set to 0.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.136.1.8.2.10.1.5

hwY1731TestIdTwoDelayOnDemandStartTime DateAndTime

Read-only

This object indicates the date and time when on-demand two-way delay measurement starts.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

No entry can be created in this table.

Modification Restriction

Entries in this table cannot be modified.

Deletion Restriction

Entries in this table cannot be deleted.

Access Restriction

Entries in this table can be read only after CFM has been enabled globally.