MIB Reference

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwFanStatusTable

hwFanStatusTable

This table describes the presence, running status, speed adjustment mode, and speed of fans on a device.

The indexes of this table are hwEntityFanSlot and hwEntityFanSn.

NOTE:

This table is not supported on the AR150-S&AR160-S&AR200-S series.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.31.1.1.10.1.1

hwEntityFanSlot

Integer32

read-only

This object indicates the slot ID of a card.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.10.1.2

hwEntityFanSn

Integer32

read-only

This object indicates the index of a fan.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.10.1.3

hwEntityFanReg

INTEGER

read-only

This object indicates that whether a fan has registered.

The value can be:
  • 1: yes (registered)
  • 2: no (unregistered)

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.10.1.4

hwEntityFanSpdAdjMode

INTEGER

read-only

This object indicates the fan speed adjustment mode.

The value can be:
  • 1: auto (automatic mode)
  • 2: manual (manual mode)
The default value is auto.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.10.1.5

hwEntityFanSpeed

Integer32

read-only

This object indicates the fan speed, in percentage.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.10.1.6

hwEntityFanPresent

INTEGER

read-only

This object indicates whether a fan is installed in the slot.

The value can be:
  • 1: present
  • 2: absent

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.31.1.1.10.1.7

hwEntityFanState

INTEGER

read-only

This object indicates the running status of a fan.

The value can be:
  • 1: normal
  • 2: abnormal

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

None.