MIB Reference

AR100-S, AR110-S, AR120-S, AR150-S, AR160-S, AR200-S, AR1200-S, AR2200-S, and AR3200-S V200R009

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntFxoPortOperTable

hwEntFxoPortOperTable

This table is used to maintain and query FXO port status and uses S/S/P as the index for this port.

The index of this table is hwEntFxoPortOperIndex.

The table entry of this table is hwEntFxoPortOperEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.252.9.1.1

hwEntFxoPortOperIndex

Integer32

This object indicates the port operation index.

not-accessible

current

1.3.6.1.4.1.2011.5.25.252.9.1.2

hwEntFxoPortSrvState

INTEGER

This object indicates the physical status.

The options are as follows:

  • 1: normal
  • 2: fault
  • 3: deactive
  • 4: powredeny

Read-only

Current

1.3.6.1.4.1.2011.5.25.252.9.1.3

hwEntFxoPortAdminState

INTEGER

This object indicates the management status.

The options are as follows:

  • 1: noLoopNoTest
  • 2: noLoopTest
  • 3: localLoopNoTest
  • 4: localLoopTest
  • 5: remoteLoopNoTest
  • 6: remoteLoopTest

Read-only

Current

1.3.6.1.4.1.2011.5.25.252.9.1.4

hwEntFxoPortLineState

INTEGER

This object indicates the line status.

The options are as follows:

  • 1: normal
  • 2: fault
  • 3: unknown

Read-only

Current

1.3.6.1.4.1.2011.5.25.252.9.1.5

hwEntFxoPortAdminOper

INTEGER

This object indicates the port operations.

The options are as follows:

  • 1: remoteLoop
  • 2: localLoop
  • 3: cancelLoop

Read-write

Current

Creation Restriction

No entry can be created in this table.

Modification Restriction

Currently, FXO ports do not support remote loop operations.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

None.

Translation
Download
Updated: 2019-07-19

Document ID: EDOC1000174090

Views: 500605

Downloads: 49

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next