Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwCBQoSClassifierCfgInfoTable

hwCBQoSClassifierCfgInfoTable

This table configures traffic classifiers. It describes some mandatory variables for classifying traffic. There are system-defined traffic classifiers and user-defined traffic classifiers. The system-defined classifiers cannot be created, modified, or deleted.

The index of this table is hwCBQoSClassifierIndex.

OID

Object Name

Syntax

Description

Max Access

Implemented Specifications

1.3.6.1.4.1.2011.5.25.32.1.1.1.2.1.1

hwCBQoSClassifierIndex

Integer32

This object indicates the traffic classifier index. The value ranges from 0 to 1024.

Default value: none.

Read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.32.1.1.1.2.1.2

hwCBQoSClassifierName

Octet String

This object indicates the traffic classifier name. The value is a string of 1 to 31 ASCII characters without spaces.

Default value: none.

Spaces at the beginning or end of the string will be ignored.

Read-create

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.32.1.1.1.2.1.3

hwCBQoSClassifierRuleCount

Integer32

This object indicates the number of rules in a traffic classifier. The value ranges from 0 to 1023.

Default value: none.

Read-only

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.32.1.1.1.2.1.4

hwCBQoSClassifierOperator

Integer

This object indicates the relationship between rules in a traffic classifier:

  • 1: AND
  • 2: OR

Read-create

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.32.1.1.1.2.1.6

hwCBQoSClassifierRowStatus

RowStatus

This object indicates the row status:

  • 1: active
  • 4: createandgo
  • 6: destroy

Default value: none.

Read-create

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

  • The number of created traffic classifiers cannot exceed 1024; otherwise, an error message is displayed.

  • hwCBQoSClassifierIndex must be the same as the value of hwCBQoSClassifierIndexNext.

  • hwCBQoSClassifierName must be configured and its value must be unique; otherwise, an error message is displayed.

  • hwCBQoSClassifierRuleCount indicates the number of rules. A created rule has a number allocated by the system. The rule number starts from 0. The value is the same as hwCBQoSMatchRuleIndex in hwCBQoSMatchRuleCfgInfoTable, and is read-only.

  • hwCBQoSClassifierLayer cannot be created.

  • To create a row, set hwCBQoSClassifierRowStatus to createAndGo(4). A row cannot be created by using createAndWait(5).

Modification Restriction

No entry in this table can be modified.

Deletion Restriction

To delete a traffic classifier, delete all the traffic policies that reference the traffic classifier. That is, delete all the rows whose hwCBQoSPolicyClassName values are hwCBQoSClassifierName in hwCBQoSPolicyClassCfgInfoTable.

Access Restriction

None.

Translation
Download
Updated: 2019-07-19

Document ID: EDOC1000174090

Views: 509397

Downloads: 49

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next