Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwEntPbxSignalTraceConfigTable

hwEntPbxSignalTraceConfigTable

This table is used to configure signaling diagnosis.

The index of this table is hwEntPbxSignalTraceTaskNo.

The table entry of this table is hwEntPbxSignalTraceConfigEntry.

OID

Object Name

Data Type

Description

Maximum Access Permission

Status

1.3.6.1.4.1.2011.5.25.313.58.1.1

hwEntPbxSignalTraceTaskNo

Integer32

This object indicates the task ID of signaling diagnosis.

Value range: 0 to 2147483647

Not-accessible

Current

1.3.6.1.4.1.2011.5.25.313.58.1.2

hwEntPbxSignalTraceRowStatus

RowStatus

This object indicates the row status.

The options are as follows:

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy
NOTE:

Currently, only createAndGo and destroy are supported.

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.3

hwEntPbxSignalTraceTaskID

Integer32

This object indicates the session ID.

Value range: 0 to 2147483647

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.4

hwEntPbxSignalTraceTarget

INTEGER

This object indicates the protocol type of signaling diagnosis.

The options are as follows:

  • 1: sip
  • 2: pra
  • 3: r2
  • 4: user
  • 5: bra

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.5

hwEntPbxSignalTraceSipIp

IpAddress

This object indicates the IP address of the peer device diagnosed using SIP signaling.

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.6

hwEntPbxSignalTraceTrkIndex

Integer32

This object indicates the slot number, subcard number, and port number diagnosed using PRA signaling.

The options are as follows:

bits 24-31: slot index

bits 23-16: subcard index

bits 15-8: port index

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.7

hwEntPbxSignalTraceStartTS

Integer32

This object indicates the start timeslot for R2 signaling diagnosis.

Value range: 0 to 65534

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.8

hwEntPbxSignalTraceEndTS

Integer32

This object indicates the end timeslot for R2 signaling diagnosis.

Value range: 0 to 65534

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.9

hwEntPbxSignalTraceDn

DisplayString

This object indicates the diagnosed number.

Length: a string of 1 to 16 digits

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.10

hwEntPbxSignalTraceEntName

DisplayString

This object indicates the name of the diagnosed enterprise.

Length: a string of 1 to 32 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.11

hwEntPbxSignalTraceFilter

Integer32

This object indicates the filtering criterion.

Value range: 0 to 65534

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.12

hwEntPbxSignalTraceSequence

Unsigned32

This object indicates the sequence number of signaling diagnosis.

Value range: 0 to 4294967295

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.13

hwEntPbxSignalTraceServerIp

IpAddress

This object indicates the IP address of the server for receiving signaling messages, which is generally the IP address of the NMS.

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.14

hwEntPbxSignalTraceServerPort

Integer32

This object indicates the port for receiving signaling messages, which is generally the SFTP port in the NMS.

Value range: 0 to 65534

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.15

hwEntPbxSignalTraceServerUserName

DisplayString

This object indicates the SFTP user name of the server for receiving signaling messages.

Length: a string of 1 to 32 characters

Read-create

Current

1.3.6.1.4.1.2011.5.25.313.58.1.16

hwEntPbxSignalTraceServerPassword

DisplayString

This object indicates the SFTP password of the server for receiving signaling messages.

Length: a string of 1 to 32 characters

Read-create

Current

Creation Restriction

None.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

None.

Translation
Download
Updated: 2019-07-19

Document ID: EDOC1000174090

Views: 480963

Downloads: 48

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next