Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Maintenance

Maintenance

Clearing Alarms and Events

Context

The cleared alarm or event statistics cannot be restored. Confirm the action before you run the command.

Procedure

  • Clear alarms.
    1. Run:

      system-view

      The system view is displayed.

    2. Run:

      alarm

      The alarm view is displayed.

    3. Run:

      clear alarm active { all | sequence-number sequence-number  }

      Active alarms on the device are cleared.

  • Clear events.
    1. Run:

      system-view

      The system view is displayed.

    2. Run:

      event

      The event view is displayed.

    3. Run:

      clear event all

      Events on the device are cleared.

Monitoring Alarms and Events

Procedure

  • Monitor alarms.

    • Run:

      display alarm active

      Active alarms on the device are displayed.

    • Run:

      display alarm history

      Historical alarms on the device are displayed.

  • Monitor events.

    • Run:

      display event

      Events on the device are displayed.