Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Alarm Function on an AP

Configuring the Alarm Function on an AP

Context

  • You can configure alarm thresholds on an AP to monitor the AP in real time. When the configured thresholds are exceeded, the AP generates alarms or logs.

    The default alarm thresholds are recommended.

Procedure

  1. Run:

    system-view

    The system view is displayed.

  2. Run:

    wlan

    The WLAN view is displayed.

  3. Run:

    high-temperature threshold threshold-value

    A high temperature alarm threshold is configured for an AP.

    Table 10-1  Default upper temperature alarm threshold for APs

    AP Model

    Default Value (°C)

    AP4030DN/AP4050DN-S/AP4051DN/AP4151DN

    55

    AP4050DN/AP1050DN-S

    96

    AP5030DN/AP5130DN

    87

    AP8030DN/AP8130DN/AP8050DN/AP8150DN

    83

    AP8030DN

    86

    AP8130DN

    88

    AP9130DN

    86

    AP9131DN/AP9132DN

    84

    AP4030TN/AP6150DN

    50

    AP6050DN

    86

    AP7050DE

    88

    AP7050DN-E

    89

    NOTE:

    The AP4030DN, AP4050DN-S, AP4051DN, AP4151DN, , AP2050DN, AP2050DN-E, AP4050DN-E, AP4050DN-HD, and AP4130DN do not support this command.

  4. Run:

    low-temperature threshold threshold-value

    A low temperature alarm threshold is configured for an AP.

    Table 10-2  Default lower temperature alarm threshold for APs

    AP Model

    Default Value (°C)

    AP8030DN/AP8050DN/AP8050DN-S/AP8150DN/AP8130DN/AP9130DN/AP9131DN/AP9132DN

    -43

    AP5030DN/AP5130DN

    -28

    AP4030TN/AP6150DN

    -10

    AP6050DN/AP7050DN-E/AP7050DE

    -13

    NOTE:

    The AP4030DN, AP4050DN-S, AP4051DN, AP4151DN, , AP2050DN, AP2050DN-E, AP4050DN-E, AP4050DN-HD, and AP4130DN do not support this command.