Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Logging In to the Device Through STelnet

Logging In to the Device Through STelnet

Pre-configuration Tasks

Before logging in to the device through STelnet, complete the following tasks:

  • Start the device properly.
  • Prepare network cables used to connect device interfaces.
  • Configure the PC's IP address and subnet mask. The IP address must be on the network segment 169.254.0.0/16 but cannot be 169.254.1.1. 169.254.1.100 is recommended. The subnet mask is 255.255.0.0.
NOTE:
  • Ensuring that the IP address 169.254.1.1 and subnet mask 255.255.0.0 have been configured on VLANIF 1 of the device before the delivery, and GE0/0/0 has been added to VLAN 1 by default.
  • Before the device is delivered, the STelnet service has been configured on the device. The STelnet interface number is 22, and the default user name and password are respectively admin and admin@huawei.com.
  • By default, an AP obtains a dynamic IP address through DHCP. If the AP fails to obtain an IP address through DHCP, configure the IP address 169.254.1.1 for the AP. If the AP obtains an IP address through DHCP, ensure that the PC's IP address is on the same network segment as the IP address obtained by the AP.

Procedure

  1. Use the SSH client software to log in to the device through STelnet from a terminal. The third-party software SecureCRT is used as an example here.
    1. After the device is powered on, connect the PC's network interface to GE0/0/0 of the device using network cables.

      NOTE:

      Ping 169.254.1.1 from the PC to check whether the device can be pinged successfully. If the ping operation fails, check whether the PC's IP address is correct or replace the network cable.

      The version of SecureCRT must be 8.0 or later.

    2. Use the SecureCRT software to log in to the device, enter the device IP address.

      Figure 3-2  SecureCRT Configuration page

    3. Click Open. Enter the user name and password at the prompt, and press Enter. You have logged in to the device. (The following information is only for reference.)

       -----------------------------------------------------------------------------     
        User last login information:     
        -----------------------------------------------------------------------------
        Access Type: Telnet      
        IP-Address : 169.254.1.1     
        Time       : 2017-06-19 09:52:05+00:00     
        -----------------------------------------------------------------------------
      Warning: Current license state is Demo. 52 days remain!
      <Huawei>
      NOTE:

      It is recommended that you change the initial user name and password after login. For details, see Configuring a User Interface.

  2. Confirm or configure the country code.

    Info: Current mode: Fat (working independently).                         
    Warning: The default country code is CN. Ensure that AP radio attributes comply 
    with laws and regulations in different countries. Do you want to change the coun
    try code? [Y/N]:y                                                         
    Please enter the country code:US      
    <Huawei>
    NOTE:
    Confirm or configure the country code upon the first login or empty configuration (in scenarios such as factory setting restoration and cloud/Fit mode switching to Fat mode). To modify the default country code, configure a correct country code. For details, see Table 1 in the Command Reference.

Translation