No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FusionServer Tools 2.0 uREST User Guide 16

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting VLAN Information

Setting VLAN Information

Function

Set VLAN information.

This command does not apply to E9000 server compute nodes.

Format

./urest -H HOST -p PORT -U USERNAME -P PASSWORD setvlan -S {True,False} -I VLANID

Parameters

Parameter

Description

Value

HOST

iBMC IP address or domain name. It is a mandatory parameter. If an IPv6 address is used, the IPv6 address must be included in square brackets, such as [1001::1001].

-

PORT

Port number. The default value is 443. It is an optional parameter.

Enter the port number if the default value 443 is not used.

USERNAME

iBMC user name. It is a mandatory parameter.

-

PASSWORD

Password of the iBMC user. It is a mandatory parameter.

-

{True,False}

VLAN function enabling status. It is an optional parameter.

  • True: Enable the VLAN function.
  • False: Disable the VLAN function.

VLANID

VLAN ID. It is an optional parameter.

1 to 4094

Usage Guidelines

None

Example

Obtain help information.

[root@localhost bin]# ./urest -H 10.10.10.10 -U ****** -P ****** setvlan -h 
usage: urest setvlan [-h] [-S {True,False}] [-I VLANID] 

optional arguments: 
  -h, --help       show this help message and exit 
  -S {True,False}  whether VLAN is enabled 
  -I VLANID        VLAN identifier

Set VLAN information.

[root@localhost bin]# ./urest -H 10.10.10.10 -U ****** -P ****** setvlan -S True -I 1 
Success: successfully completed request

Query VLAN information.

[root@localhost bin]# ./urest -H 10.10.10.10 -U ****** -P ****** getvlan 

VLANEnable          : True 