Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Connection Exception Occurs During In-band Access

Connection Exception Occurs During In-band Access

Solution

  1. Check whether the out-of-band access is normal. If the in-band and out-of-band access is abnormal, go to Step 2. If the out-of-band access is normal, check the in-band access operations of other uREST commands. If only the current in-band command is abnormal, go to Step 3.
  2. Check whether the SSL module is normal and whether the HTTPS service is enabled.
  3. Add --timeout=TIMEOUT to the command to set the timeout interval for accessing the iBMC Redfish interface. For details, see Using uREST tool. After the setting, check whether the in-band access is normal.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Run the lsmod command to check whether the host_edma_drv, host_cdev_drv, and host_veth_drv drivers are installed.

    • If yes, go to Step 5.
    • If no, install the host_edma_drv, host_cdev_drv, and host_veth_drv drivers.

  5. Run the ifconfig command to check whether the IPv6 service is enabled for the local link (lo) and virtual network device (veth).

    • If yes, go to Step 6.
    • If no, enable the IPv6 service for lo and veth.

  6. Run the ifconfig veth add fe80::9e7d:a3ff:fe28:6ff9/64 command and check whether the command can be executed.

  7. Run the ifconfig veth del fe80::9e7d:a3ff:fe28:6ff9 and ifconfig veth add fe80::9e7d:a3ff:fe28:6ff9/64 commands and check whether the commands can be executed.

    • If yes, go to Step 8.
    • If no, contact Huawei technical support.

  8. Run the ping6 fe80::9e7d:a3ff:fe28:6ffa%veth command to check whether the communication between the iBMA and iBMC is normal.

    • If yes, no further action is required.
    • If no, contact Huawei technical support.