Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Querying the PSU Redundancy Mode

Querying the PSU Redundancy Mode

Function

Obtain the PSU redundancy mode.

Format

./urest -H HOST -p PORT -U USERNAME -P PASSWORD getpowerredun

Parameters

Parameter

Description

Value

HOST

iBMC IP address or domain name. It is a mandatory parameter. If an IPv6 address is used, the IPv6 address must be included in square brackets, such as [1001::1001].

-

PORT

Port number. The default value is 443. It is an optional parameter.

Enter the port number if the default value 443 is not used.

USERNAME

iBMC user name. It is a mandatory parameter.

-

PASSWORD

Password of the iBMC user. It is a mandatory parameter.

-

Usage Guidelines

None

Example

Obtain the PSU redundancy mode.

[root@localhost bin]# ./urest -H 10.10.10.10 -U ****** -P ****** getpowerredun 
[ActualPSUStatus] 
Mode                : Sharing 
ActivePSU           : PS2 
------------------------------ 
[PredictedPSUStatus] 
Mode                : Sharing 
ActivePSU           : PS1     | PS2 
Health              : Warning | OK 
State               : Absent  | Enabled

System Response

Table 3-35 Output description

Parameter

Description

ActualPSUStatus

Actual PSU redundancy mode, including:

  • Mode: Sharing indicates the load balancing mode, and Failover indicates the active/standby mode.
  • ActivePSU: active PSU

PredictedPSUStatus

Expected PSU redundancy mode, including:

  • Mode: Sharing indicates the load balancing mode, and Failover indicates the active/standby mode.
  • ActivePSU: active PSU
  • Health: PSU redundancy group health status
  • State: Whether the PSU redundancy group is enabled. Absent indicates that the PSU redundancy group is disabled, and Enabled indicates that the PSU redundancy group is enabled.