Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Modifying the Smart Provisioning Service Resource Attributes

Modifying the Smart Provisioning Service Resource Attributes

Function

Modify the Smart Provisioning service resource attributes, including enabling or disabling Smart Provisioning and setting the system restart delay.

Format

./urest -H HOST -p PORT -U USERNAME -P PASSWORD setspinfo -S {True,False} -T SYSRESTARTDELAYSECONDS

Parameters

Parameter

Description

Value

HOST

iBMC IP address or domain name. It is a mandatory parameter. If an IPv6 address is used, the IPv6 address must be included in square brackets, such as [1001::1001].

-

PORT

Port number. The default value is 443. It is an optional parameter.

Enter the port number if the default value 443 is not used.

USERNAME

iBMC user name. It is a mandatory parameter.

-

PASSWORD

Password of the iBMC user. It is a mandatory parameter.

-

{True,False}

Smart Provisioning enabling or disabling. It is an optional parameter.

  • True: enabled
  • False: disabled

SYSRESTARTDELAYSECONDS

System restart latency, of which the unit is second. It is an optional parameter.

The value must be a positive number.

Usage Guidelines

  • Only FusionServer V5 servers and TaiShan 200 servers are supported. Atlas servers are not supported.
  • The BIOS version must be 0.39 or later.
  • Smart Provisioning must be installed on the server.

Example

Obtain help information.

[root@localhost bin]# ./urest -H 10.10.10.10 -U ****** -P ****** setspinfo -h 
usage: urest setspinfo [-h] [-S {True,False}] [-T SYSRESTARTDELAYSECONDS]
 
optional arguments:
  -h, --help            show this help message and exit
  -S {True,False}       SP service start state
  -T SYSRESTARTDELAYSECONDS
                        system restart delay time

If information cannot be obtained and an error message similar to "Failure: resource was not found" is displayed, handle the problem by seeing Error Message "Failure: resource was not found." Is Displayed When a User Attempts to Obtain the Smart Provisioning Information or Upgrade Smart Provisioning.

Enable Smart Provisioning.

[root@localhost bin]# ./urest -H 10.10.10.10 -U ****** -P ****** setspinfo -S True 
Success: successfully completed request