FusionServer Tools 2.0 uREST User Guide 16

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Obtaining In-Band Upgradeable Firmware

Obtaining In-Band Upgradeable Firmware

Function

Obtain in-band upgradeable firmware.

Format

./urest -H HOST -p PORT -U USERNAME -P PASSWORD --timeout=TIMEOUT getosfw

Parameters

Parameter

Description

Value

HOST

iBMC IP address or domain name. It is a mandatory parameter. If an IPv6 address is used, the IPv6 address must be included in square brackets, such as [1001::1001].

-

PORT

Port number. The default value is 443. It is an optional parameter.

Enter the port number if the default value 443 is not used.

USERNAME

iBMC user name. It is a mandatory parameter.

-

PASSWORD

Password of the iBMC user. It is a mandatory parameter.

-

TIMEOUT

Timeout interval for accessing the iBMC Redfish interface. It is an optional parameter. The default value is 30 seconds.

The value ranges from 10 to 1000, and the unit is seconds.

Usage Guidelines

To obtain the in-band upgradeable firmware of a remote server, the iBMA must be installed on the remote server and the iBMA service must be started.

Example

Obtain in-band upgradeable firmware.

[root@localhost bin]# ./urest -H 10.10.10.10 -U ****** -P ****** getosfw 
---------------------------------------- 
Name             : None 
BDF              : 0000:01:00.0 
RootBDF          : 0000:00:01.0 
Model            : SAS3108 
VendorID         : 0x1000 
DeviceID         : 0x005d 
SubsystemVendorID: 0x19e5 
SubsystemDeviceID: 0xd207 
DeviceSilkScreen : RAID Card1 
DeviceLocation   : mainboard 
---------------------------------------- 
Name             : None 
BDF              : 0000:02:00.0 
RootBDF          : 0000:00:02.0 
Model            : i350 
VendorID         : 0x8086 
DeviceID         : 0x1521 
SubsystemVendorID: 0x19e5 
SubsystemDeviceID: 0xd10c 
DeviceSilkScreen : NIC1 
DeviceLocation   : mainboard 
---------------------------------------- 
Name             : None 
BDF              : 0000:04:00.0 
RootBDF          : 0000:00:03.0 
Model            : EP2532 
VendorID         : 0x1077 
DeviceID         : 0x2532 
SubsystemVendorID: 0x1077 
SubsystemDeviceID: 0x015d 
DeviceSilkScreen : PCIe Card 4 
DeviceLocation   : mainboard 
---------------------------------------- 
Name             : None 
BDF              : 0000:05:00.0 
RootBDF          : 0000:00:03.2 
Model            : XE201 
VendorID         : 0x10df 
DeviceID         : 0xe200 
SubsystemVendorID: 0x10df 
SubsystemDeviceID: 0xe280 
DeviceSilkScreen : PCIe Card 5 
DeviceLocation   : mainboard 
----------------------------------------

System Response

Table 3-46 Output description

Parameter

Description

Name

Firmware name.

BDF

BDF number.

RootBDF

Root BDF.

Model

Module type.

VendorID

Vendor ID.

DeviceID

Device ID.

SubsystemVendorID

Vendor ID of the subdevice.

SubsystemDeviceID

Subdevice ID.

DeviceSilkScreen

Firmware silkscreen.

DeviceLocation

Firmware container.

Translation