Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Querying RAID Controller Card Information (ctrlinfo)

Querying RAID Controller Card Information (ctrlinfo)

Function

The ctrlinfo command is used to query RAID controller card information.

Format

ipmcget -t storage -d ctrlinfo -v <option>

Parameters

Parameter

Description

Value

option

Specifies the ID of a RAID controller card.

  • 0 to 255: indicates a specific RAID controller card.
  • all: indicates all RAID controller cards.

Usage Guidelines

This command can be used only when either of the following conditions is met:
  • The RAID controller card supports iBMC out-of-band management. You can refer to the Technical Specifications section in the RAID controller card user guide to determined whether the RAID card supports the iBMC out-of-band management..
  • The iBMA 2.0 has started on the OS.

Example

# Query information about RAID controller card 0.

iBMC:/->ipmcget –t storage -d ctrlinfo –v 0 
RAID Controller #0 Information
----------------------------------------------------------------------
Controller Name                               : SAS3108
Controller Type                               : LSI SAS3108
Component Name                                : RAID Card1
Support Out-of-Band Management                : Yes
Controller Mode                               : RAID
Controller Health                             : Normal
Firmware Version                              : 4.650.00-6121
NVDATA Version                                : 3.1602.00-0002
Memory Size                                   : 1024 MB
Device Interface                              : SAS 12G
SAS Address                                   : 5e00000157737cd6
Minimum Strip Size Supported                  : 64 KB
Maximum Strip Size Supported                  : 1 MB
Controller Cache Is Pinned                    : No
Maintain PD Fail History across Reboot        : Yes
Copyback Enabled                              : No
Copyback on SMART error Enabled               : No
JBOD Enabled                                  : No
DDR ECC Count                                 : 0

BBU Status                                    : Present
BBU Type                                      : CVPM02
BBU Health                                    : Normal


PHY Status                                    : 
    PHY #0 :
        Invalid Dword Count           : 0
        Loss Dword Sync Count         : 0
        PHY Reset Problem Count       : 0
        Running Disparity Error Count : 0

    PHY #1 :
        Invalid Dword Count           : 0
        Loss Dword Sync Count         : 0
        PHY Reset Problem Count       : 0
        Running Disparity Error Count : 0

    PHY #2 :
        Invalid Dword Count           : 0
        Loss Dword Sync Count         : 0
        PHY Reset Problem Count       : 0
        Running Disparity Error Count : 0

    PHY #3 :
        Invalid Dword Count           : 0
        Loss Dword Sync Count         : 0
        PHY Reset Problem Count       : 0
        Running Disparity Error Count : 0

    PHY #4 :
        Invalid Dword Count           : 0
        Loss Dword Sync Count         : 0
        PHY Reset Problem Count       : 0
        Running Disparity Error Count : 0

    PHY #5 :
        Invalid Dword Count           : 0
        Loss Dword Sync Count         : 0
        PHY Reset Problem Count       : 0
        Running Disparity Error Count : 0

    PHY #6 :
        Invalid Dword Count           : 0
        Loss Dword Sync Count         : 0
        PHY Reset Problem Count       : 0
        Running Disparity Error Count : 0

    PHY #7 :
        Invalid Dword Count           : 0
        Loss Dword Sync Count         : 0
        PHY Reset Problem Count       : 0
        Running Disparity Error Count : 0
----------------------------------------------------------------------