No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Huawei Rack Server iBMC (V260 to V278) User Guide 11

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting the Method for Obtaining NTP Information (ntp -d mode)

Setting the Method for Obtaining NTP Information (ntp -d mode)

Function

The ntp -d mode command is used to set how to obtain NTP information.

Format

ipmcset -t ntp -d mode -v mode

Parameters

Parameter

Description

Value

mode Indicates how to obtain NTP information.
  • manual: Manually set NTP information.
  • dhcpv4: Automatically obtain NTP information using DHCPv4.
  • dhcpv6: Automatically obtain NTP information using DHCPv6.

Usage Guidelines

If mode is DHCPv4, you do not need to set the time zone data.

Example

# Enable NTP information to be manually set.

iBMC:/->ipmcset -t ntp -d mode -v manual
Set NTP mode (manual) successfully.

# Query NTP information.

iBMC:/->ipmcget -d ntpinfo
Status : enabled
Mode               : manual
Preferred Server   : 192.168.2.26
Alternative Server : 192.168.2.99
Synchronize        : successful
Auth Enable        : disabled
Group Key          : not imported