Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Querying and Setting the Server Power-Off Timeout Period (shutdowntimeout)

Querying and Setting the Server Power-Off Timeout Period (shutdowntimeout)

Function

The shutdowntimeout command is used to query and set the power-off timeout period for the server.

After a power-off operation is performed, the iBMC waits for the OS to shut down. If the OS fails to shut down within the specified time, the iBMC will forcibly power off the server.

Format

ipmcget [-t fru0] -d shutdowntimeout

ipmcset [-t fru0] -d shutdowntimeout -v <time>

Parameters

Parameter Description Value
time

Specifies the maximum time (in seconds) for shutting down the OS.

Value range: 0, 10 to 6000

The value 0 indicates that the shutdown timeout is disabled.

Usage Guidelines

  • If Power-off Timeout Period is set to on the iBMC WebUI, you can use this command to disable shutdown timeout or set the shutdown timeout period as required.
  • If Power-off Timeout Period is set to on the iBMC WebUI, you can use this command to set the shutdown timeout period. After the setting, Power-off Timeout Period changes to on the iBMC WebUI.

Example

# Set the shutdown timeout period to 600 seconds for the server.

iBMC:/->ipmcset -d shutdowntimeout -v 600
Set shutdown timeout successfully.

# Query the shutdown timeout period.

iBMC:/->ipmcget -d shutdowntimeout
Graceful shutdown timeout state:    enabled
Graceful shutdown timeout value:    600 s

# Query the shutdown timeout period (power-off timeout period is set to OFF on the iBMC WebUI).

iBMC:/->ipmcget -d shutdowntimeout
Graceful shutdown timeout state:    disabled

# Disable shutdown timeout for the server.

iBMC:/->ipmcset -d shutdowntimeout -v 0
Set shutdown timeout successfully.