Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Querying and Setting the Cooling Power Mode (coolingpowermode)

Querying and Setting the Cooling Power Mode (coolingpowermode)

Function

The coolingpowermode command is used to set and query the server cooling power mode.

Format

ipmcget -t maintenance -d coolingpowermode

ipmcset -t maintenance -d coolingpowermode -v <option>

Parameters

Parameter

Parameter Description

Value

option

Indicates the server cooling power mode.

  • 0: indicates the low cooling power mode.
  • 1: indicates the high cooling power mode.

Usage Guidelines

This command can be used only on the RH8100 V3 and 8100 V5. In dual-system mode, the fan cooling power mode can be set only on the active system.

Example

# Set the server cooling power mode to the low cooling power mode.

iBMC:/-> ipmcset -t maintenance -d coolingpowermode -v 0
Set cooling power mode to [Power saving mode] successfully.

# Query the current cooling power mode.

iBMC:/-> ipmcget -t maintenance -d coolingpowermode
Power saving mode