No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Huawei Rack Server iBMC (V260 to V278) User Guide 12

Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting the Fan Speed (fanlevel)

Setting the Fan Speed (fanlevel)

Function

The fanlevel command is used to set the fan speed.

Format

ipmcset -d fanlevel -v <fanlevel> [fanid]

Parameters

Parameter Description Value
fanlevel Indicates the percentage of the current fan speed to the full fan speed. The value is an integer.

The value range varies with the server model.

fanid Indicates the ID of the fan.

The value range varies with the server model.

Usage Guidelines

If the fan ID is not specified, the command sets the fan rotation speed for all fans.

Example

# Set the speed of fan 2 to 50% of the full speed.

iBMC:/->ipmcset -d fanlevel -v 50 2
Set fan(2) level to (50%) successfully.
Current Mode           :   Auto 
iBMC:/->ipmcset -d fanlevel -v 50  
Set fan level successfully.
Current Mode           :   Auto 
Global Manual Fan Level:   50%
Download
Updated: 2019-06-04

Document ID: EDOC1000177670

Views: 125071

Downloads: 587