Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Querying and Setting Controlled Power-on Configuration (poweronpermit)

Querying and Setting Controlled Power-on Configuration (poweronpermit)

Function

The poweronpermit command is used to query and set the controlled power-on function.

Format

ipmcget -d poweronpermit

ipmcset -d poweronpermit -v <enable | disable> [ip] [netport]

Parameters

Parameter Description Value

enable

Enables the controlled power-on function.

-

disable

Disables the controlled power-on function.

-

ip

Specifies the server IP address.

-

netport

Specifies the port number.

0 to 65535

Usage Guidelines

None

Example

# Query configuration of the controlled power-on function.

iBMC:/->ipmcget -d poweronpermit
State         : enabled
ManagerIP     : 192.168.1.1
ManagerPort   : 26957

# Enable the controlled power-on function.

iBMC:/->ipmcset -d poweronpermit -v enable 192.168.1.1 26957
Set poweronpermit successfully.