Configuration File Description
Table 9-1, Table 9-2, and Table 9-3 describe the parameters in iBMC, BIOS, and RAID controller card configuration files.
To ensure data security, some of the iBMC and RAID controller configuration in the configuration file imported after the mainboard replacement do not take effect.
The iBMC configuration, BIOS configuration, and some RAID controller configuration can be imported and exported.
Type |
Exported Parameter |
Exported Subparameter |
Description |
Valid After Imported via Configuration File |
---|---|---|---|---|
Local user |
User |
UserName |
Specifies the name of a user. |
Yes |
User |
PassWord |
Specifies the password of a user. |
No Sensitive information is displayed in ciphertext in the configuration file and does not take effect after the configuration file is imported. |
|
User |
Privilege |
Specifies the rights of a user. |
Yes |
|
User |
UserRoleId |
Specifies the role of a user. |
Yes |
|
User |
PermitRuleIds |
Specifies the login rules for a user. |
Yes |
|
User |
LoginInterface |
Specifies the login interface for a user. |
Yes |
|
User |
IsUserEnable |
Specifies whether the user is enabled. |
No The value is displayed in the configuration file. |
|
User |
IsUserLocked |
Specifies whether the user is locked. |
No The value is displayed in the configuration file. |
|
UserRole |
KVMMgnt |
Specifies the KVM rights. |
Yes |
|
UserRole |
UserMgnt |
Specifies the user management rights. |
Yes |
|
UserRole |
VMMMgnt |
Specifies the VMM rights. |
Yes |
|
UserRole |
BasicSetting |
Specifies the rights for performing basic settings. |
Yes |
|
UserRole |
ReadOnly |
Specifies the read-only rights. |
Yes |
|
UserRole |
PowerMgnt |
Specifies the power control rights. |
Yes |
|
UserRole |
DiagnoseMgnt |
Specifies the debugging and diagnosis rights. |
Yes |
|
UserRole |
ConfigureSelf |
Specifies the rights for configuring the user's own data. |
Yes |
|
UserRole |
SecurityMgnt |
Specifies the security configuration rights. |
Yes |
|
Two-factor authentication |
MutualAuthentication |
MutualAuthenticationState |
Specifies whether two-factor authentication is enabled. |
Yes |
MutualAuthentication |
MutualAuthenticationOCSP |
Specifies whether the two-factor authentication revocation check is enabled. |
Yes |
|
LDAP configuration |
LDAP |
Enable |
Specifies whether LDAP is enabled. |
Yes |
LDAP |
CertStatus |
Specifies whether LDAP certificate verification is enabled. |
Yes |
|
LDAP |
HostAddr |
Specifies the LDAP server address. |
Yes |
|
LDAP |
Port |
Specifies the LDAPS port number. |
Yes |
|
LDAP |
UserDomain |
Specifies the domain name. |
Yes |
|
LDAP |
Folder |
Specifies the folder for which user applications are stored. |
Yes |
|
LDAP |
BindDN |
Specifies the distinguished name of an LDAP proxy user. |
Yes |
|
LDAP |
BindDNPsw |
Specifies the password of the LDAP proxy user. |
No The value is displayed in the configuration file. |
|
LDAPServer |
Enable |
Specifies whether LDAP is enabled. |
Yes |
|
LDAPServer |
CertStatus |
Specifies whether LDAP certificate verification is enabled. |
Yes |
|
LDAPServer |
HostAddr |
Specifies the LDAP server address. |
Yes |
|
LDAPServer |
Port |
Specifies the LDAPS port number. |
Yes |
|
LDAPServer |
UserDomain |
Specifies the domain name. |
Yes |
|
LDAPServer |
Folder |
Specifies the user application folder. |
Yes |
|
LDAPServer |
BindDN |
Specifies the distinguished name of an LDAP proxy user. |
Yes |
|
LDAPServer |
BindDNPsw |
Specifies the user password. |
No The value is displayed in the configuration file. |
|
LDAPGroup |
GroupName |
Specifies the LDAP group name. |
Yes |
|
LDAPGroup |
GroupFolder |
Specifies the application folder for an LDAP group. |
Yes |
|
LDAPGroup |
GroupPermitRuleIds |
Specifies the login rules for an LDAP group. |
Yes |
|
LDAPGroup |
GroupLoginInterface |
Specifies the login interface for an LDAP group. |
Yes |
|
LDAPGroup |
GroupPrivilege |
Specifies the rights of an LDAP group. |
Yes |
|
Security hardening |
PasswdSetting |
EnableStrongPassword |
Specifies whether password complexity check is enabled. |
Yes |
SecurityEnhance |
SSHPasswordAuthentication |
Specifies whether SSH password authentication is enabled. |
Yes |
|
SecurityEnhance |
UserInactTimeLimit |
Specifies the time limit for which a user is inactive. |
Yes |
|
SecurityEnhance |
PwdExpiredTime |
Specifies the validity period of a password. |
Yes |
|
SecurityEnhance |
MinimumPwdAge |
Specifies the minimum validity period of a password. |
Yes |
|
SecurityEnhance |
InitialPwdPrompt |
Specifies whether to enable the function of prompting the user to change the password. |
Yes |
|
SecurityEnhance |
ExcludeUser |
Specifies the user who can log in to the system in emergencies. |
Yes |
|
SecurityEnhance |
OldPwdCount |
Specifies the previous password that cannot be used. |
Yes |
|
SecurityEnhance |
AuthFailMax |
Specifies the maximum number of failed login attempts allowed before a user account is locked. |
Yes |
|
SecurityEnhance |
AuthFailLockTime |
Specifies the user lockout period. |
Yes |
|
PermitRule |
TimeRuleInfo |
Specifies the rules for time-based logins. |
Yes |
|
PermitRule |
IpRuleInfo |
Specifies the rules for IP-based logins. |
Yes |
|
PermitRule |
MacRuleInfo |
Specifies the rules for MAC-based logins. |
Yes |
|
SecurityEnhance |
PermitRuleIds |
Specifies whether rules are enabled. |
Yes |
|
SecurityEnhance |
BannerState |
Specifies whether login security information configuration is enabled. |
Yes |
|
SecurityEnhance |
BannerContent |
Provides the login security information. |
Yes |
|
Network configuration |
BMC |
HostName |
Specifies the iBMC host name. |
No The value is displayed in the configuration file. |
EthGroup |
NetMode |
Specifies the network port mode. |
Yes |
|
EthGroup |
ActivePort |
Specifies the management network port. |
Yes |
|
EthGroup |
IpVersion |
Specifies whether IP is enabled. |
Yes |
|
EthGroup |
IpMode |
Specifies how IPv4 addresses are assigned. |
Yes |
|
EthGroup |
IpAddr |
Specifies an IPv4 address. |
No The value is displayed in the configuration file. |
|
EthGroup |
SubnetMask |
Specifies an IPv4 subnet mask. |
No The value is displayed in the configuration file. |
|
EthGroup |
DefaultGateway |
Specifies the default IPv4 gateway IP address. |
No The value is displayed in the configuration file. |
|
EthGroup |
Ipv6Mode |
Specifies how IPv6 addresses are allocated. |
Yes |
|
EthGroup |
Ipv6Addr |
Specifies an IPv6 address. |
No The value is displayed in the configuration file. |
|
EthGroup |
Ipv6Prefix |
Specifies the prefix length of an IPv6 address. |
No The value is displayed in the configuration file. |
|
EthGroup |
Ipv6DefaultGateway |
Specifies the default IPv6 gateway IP address. |
No The value is displayed in the configuration file. |
|
DNSSetting |
IPVer |
Specifies the IP version bound with the DNS. |
Yes |
|
DNSSetting |
Mode |
Specifies how the DNS addresses are assigned. |
Yes |
|
DNSSetting |
PrimaryDomain |
Specifies the preferred DNS server. |
Yes |
|
DNSSetting |
BackupDomain |
Specifies the alternate DNS server. |
Yes |
|
DNSSetting |
DomainName |
Specifies the DNS domain name. |
Yes |
|
EthGroup |
VlanState |
Specifies whether VLAN is enabled. |
Yes |
|
EthGroup |
VlanID |
Specifies the VLAN ID. |
Yes |
|
NTP |
EnableStatus |
Specifies whether NTP is enabled. |
Yes |
|
NTP |
Mode |
Specifies the NTP mode. |
Yes |
|
NTP |
PreferredServer |
Specifies the address of the preferred NTP server. |
Yes |
|
NTP |
AlternativeServer |
Specifies the address of the alternate NTP server. |
Yes |
|
NTP |
AuthEnableStatus |
Specifies whether NTP server authentication is enabled. |
Yes |
|
NTP |
MinPollInterval |
Specifies the minimum NTP synchronization interval. |
Yes |
|
NTP |
MaxPollInterval |
Specifies the maximum NTP synchronization interval. |
Yes |
|
VNC |
EnableState |
Specifies whether VNC is enabled. |
Yes |
|
VNC |
Password |
Specifies the VNC password. |
No Sensitive information is displayed in ciphertext in the configuration file and does not take effect after the configuration file is imported. |
|
VNC |
Timeout |
Specifies the validity period of the VNC password. |
Yes |
|
VNC |
SSLEnableState |
Specifies whether the SSL is enabled. |
Yes |
|
VNC |
Port |
Specifies the VNC service port number. |
Yes |
|
VNC |
KeyboardLayout |
Specifies the keyboard layout. |
Yes |
|
VNC |
PermitRuleIds |
Specifies the login rules. |
Yes |
|
BMC |
TimeZoneStr |
Specifies the time zone. |
Yes |
|
Service configuration |
SSH |
State |
Specifies whether SSH is enabled. |
Yes |
SSH |
Port |
Specifies the SSH port number. |
Yes |
|
Snmp |
State |
Specifies whether SNMP Agent is enabled. |
Yes |
|
Snmp |
PortID |
Specifies the SNMP Agent. |
Yes |
|
Kvm |
State |
Specifies whether KVM is enabled. |
Yes |
|
Kvm |
Port |
Specifies the KVM port number. |
Yes |
|
Vmm |
State |
Specifies whether VMM is enabled. |
Yes |
|
Vmm |
Port |
Specifies the VMM port number. |
Yes |
|
Video |
State |
Specifies whether Video is enabled. |
Yes |
|
Video |
Port |
Specifies the Video port number. |
Yes |
|
WEBHTTP |
State |
Specifies whether HTTP is enabled. |
Yes |
|
WEBHTTP |
Port |
Specifies the HTTP port number. |
Yes |
|
WEBHTTPS |
State |
Specifies whether HTTPS is enabled. |
Yes |
|
WEBHTTPS |
Port |
Specifies the HTTPS port number. |
Yes |
|
RmcpConfig |
LanState |
Specifies whether IPMI LAN (RMCP) is enabled. |
Yes |
|
RmcpConfig |
Port1 |
Specifies the IPMI LAN (RMCP) port 1. |
Yes |
|
RmcpConfig |
Port2 |
Specifies the IPMI LAN (RMCP) port 2. |
Yes |
|
RmcpConfig |
LanPlusState |
Specifies whether IPMI LAN (RMCP+) is enabled. |
Yes |
|
System configuration |
Snmp |
V1State |
Specifies whether SNMPv1 is supported. |
Yes |
Snmp |
V2CState |
Specifies whether SNMPv2c is supported. |
Yes |
|
Snmp |
LongPasswordEnable |
Specifies whether long passwords are enabled. |
Yes |
|
Snmp |
ROCommunity |
Specifies the read-only community string. |
No Sensitive information is displayed in ciphertext in the configuration file and does not take effect after the configuration file is imported. |
|
Snmp |
RWCommunity |
Specifies the read-write community string. |
No Sensitive information is displayed in ciphertext in the configuration file and does not take effect after the configuration file is imported. |
|
Snmp |
RWCommunityState |
Specifies whether the read/write community name is enabled. |
Yes |
|
Snmp |
SNMPV1V2CPermitRuleIds |
Specifies the SNMP login rules. |
Yes |
|
Snmp |
AuthProtocol |
Specifies the SNMPv3 authentication algorithm. |
Yes |
|
Snmp |
PrivProtocol |
Specifies the SNMPv3 encryption algorithm. |
Yes |
|
SecurityEnhance |
TLSVersion |
Specifies the TLS version. |
Yes |
|
SecurityEnhance |
EnableUserMgnt |
Specifies whether user management on the service side is enabled. |
Yes |
|
Session |
Timeout |
Specifies the timeout period for a web session. |
Yes |
|
Session |
Mode |
Specifies the web session mode. |
Yes |
|
BMC |
LocationInfo |
Specifies the equipment location. |
No The value is displayed in the configuration file. |
|
MeInfo |
CpuUtiliseThre |
Specifies the CPU usage alarm threshold. |
Yes |
|
MeInfo |
MemUtiliseThre |
Specifies the memory usage alarm threshold. |
Yes |
|
MeInfo |
DiskPartitionUsageThre |
Specifies the hard disk partition usage alarm threshold. |
Yes |
|
Partition |
RAIDMode |
Specifies the RAID working mode (RH8100 only) |
Yes |
|
PRODUCT |
WOLState |
Specifies whether Wake on LAN (WOL) is enabled. |
Yes |
|
System boot option |
Bios |
StartOption |
Specifies the first boot device. |
Yes |
Bios |
StartOptionFlag |
Specifies whether the boot setting takes effect permanently or just for one time only. |
Yes |
|
Alarm settings |
SyslogConfig |
EnableState |
Specifies whether Syslog is enabled. |
Yes |
SyslogConfig |
MsgIdentity |
Identifies the Syslog host. |
Yes |
|
SyslogConfig |
MsgSeverity |
Specifies Syslog alarm severity level. |
Yes |
|
SyslogConfig |
NetProtocol |
Specifies the Syslog transmission protocol. |
Yes |
|
SyslogConfig |
AuthType |
Specifies the Syslog authentication mode. |
Yes |
|
SyslogItemCfg |
EnableState |
Specifies whether the Syslog server is enabled. |
Yes |
|
SyslogItemCfg |
DestAddr |
Specifies the Syslog server address. |
Yes |
|
SyslogItemCfg |
DestPort |
Specifies the Syslog server port number. |
Yes |
|
SyslogItemCfg |
LogSrcMask |
Specifies the Syslog log type. |
Yes |
|
TrapConfig |
TrapEnable |
Specifies whether Trap is enabled. |
Yes |
|
TrapConfig |
TrapVersion |
Specifies the Trap version. |
Yes |
|
TrapConfig |
Trapv3Userid |
Specifies the SNMPv3 user name. |
Yes |
|
TrapConfig |
TrapMode |
Specifies Trap mode. |
Yes |
|
TrapConfig |
TrapIdentity |
Identifies the Trap host. |
Yes |
|
TrapConfig |
CommunityName |
Specifies the Trap community name. |
No Sensitive information is displayed in ciphertext in the configuration file and does not take effect after the configuration file is imported. |
|
TrapConfig |
SendSeverity |
Specifies the severity level for sending a Trap alarm. |
Yes |
|
TrapItemCfg |
ItemEnable |
Specifies whether the Trap server is enabled. |
Yes |
|
TrapItemCfg |
DestIpAddr |
Specifies the Trap server address. |
Yes |
|
TrapItemCfg |
DestIpPort |
Specifies the Trap server port number. |
Yes |
|
TrapItemCfg |
Separator |
Specifies the delimiter to be used in a message. |
Yes |
|
TrapItemCfg |
Time |
Specifies the message content (time). |
Yes |
|
TrapItemCfg |
SensorName |
Specifies the message content (sensor name). |
Yes |
|
TrapItemCfg |
Severity |
Specifies the message content (severity level). |
Yes |
|
TrapItemCfg |
EventCode |
Specifies the message content (event code). |
Yes |
|
TrapItemCfg |
EventDesc |
Specifies the message content (event description). |
Yes |
|
TrapItemCfg |
ShowKeyWord |
Specifies whether to display the keywords in a message. |
Yes |
|
SmtpConfig |
SmtpEnable |
Specifies whether SMTP is enabled. |
Yes |
|
SmtpConfig |
SmtpServer |
Specifies the SMTP address. |
Yes |
|
SmtpConfig |
TlsSendMode |
Specifies whether TLS is enabled. |
Yes |
|
SmtpConfig |
AnonymousMode |
Specifies whether anonymous login is enabled. |
Yes |
|
SmtpConfig |
LoginName |
Specifies the email sender name. |
Yes |
|
SmtpConfig |
LoginPasswd |
Specifies the email sender password. |
No Sensitive information is displayed in ciphertext in the configuration file and does not take effect after the configuration file is imported. |
|
SmtpConfig |
SenderName |
Specifies the mailbox address of the sender. |
Yes |
|
SmtpConfig |
TempletTopic |
Specifies the email subject. |
Yes |
|
SmtpConfig |
TempletIpaddr |
Specifies whether the email subject contains the host name. |
Yes |
|
SmtpConfig |
TempletBoardSn |
Specifies whether the email subject contains the board serial number. |
Yes |
|
SmtpConfig |
TempletAsset |
Specifies whether the email subject contains the product asset tag. |
Yes |
|
SmtpConfig |
SendSeverity |
Specifies the severity levels of the alarms to be sent. |
Yes |
|
SmtpItemCfg |
EmailName |
Specifies the recipient address. |
Yes |
|
SmtpItemCfg |
EmailDesc |
Provides information about the alarm |
Yes |
|
SmtpItemCfg |
ItemEnable |
Specifies whether alarm email notifications are sent to the recipient. |
Yes |
|
Power control |
ChassisPayload |
PowerOffTimeoutEN |
Specifies whether power-off timeout period is enabled. |
Yes |
ChassisPayload |
PowerOffTimeout |
Specifies the power-off timeout period. |
Yes |
|
ChassisPayload |
PwrButtonLock |
Specifies whether the power button on the server front panel is disabled. |
Yes |
|
ChassisPayload |
PowerRestorePolicy |
Specifies the power restore policy when the power supply is connected. |
Yes |
|
Power |
PowerCapping |
Enable |
Specifies whether power capping is enabled. |
Yes |
PowerCapping |
LimitValue |
Specifies the power cap value. |
Yes |
|
PowerCapping |
FailAction |
Specifies whether to forcibly shut down the server if the power capping fails. |
Yes |
|
Energy saving settings |
SysPower |
ExpectedMode |
Specifies the power supply working mode. |
Yes |
SysPower |
ExpectedActive |
Specifies the active power supply. |
Yes |
|
Remote control |
Kvm |
EncryptState |
Specifies whether KVM encryption is enabled. |
Yes |
Vmm |
EncryptState |
Specifies whether VMM encryption is enabled. |
Yes |
|
Kvm |
KeyboardMode |
Specifies whether persistent connection of the virtual keyboard and mouse is enabled. |
Yes |
|
Kvm |
KvmTimeout |
Specifies the remote console timeout period. |
Yes |
|
Kvm |
LocalKVMState |
Specifies whether local KVM is enabled. |
Yes |
|
Video playback |
Video |
VideoSwitch |
Specifies whether video recording is enabled. |
Yes |
Screenshot |
Kvm |
ScreenSwitch |
Specifies whether last screenshot is enabled. |
Yes |
Black box |
Diagnose |
BlackBoxState |
Specifies whether black box is enabled. |
Yes |
Serial port data |
Diagnose |
SolDataState |
Specifies whether serial port data is enabled. |
Yes |
Others |
Bios |
BiosPrintFlag |
Specifies the setting of the BIOS print switch. |
Yes |
Cooling |
Mode |
Specifies the speed adjustment mode of fans. |
No The value is displayed in the configuration file. |
|
Cooling |
PowerMode |
Specifies the power supply mode. |
Yes |
|
Cooling |
Level |
Specifies the fan speed level. |
No The value is displayed in the configuration file. |
|
Stateless |
Enable |
Specifies whether stateless computing is enabled. |
Yes |
|
Stateless |
SysManagerID |
Specifies the remote management ID. (stateless computing configuration) |
Yes |
|
Stateless |
AutoPowerOn |
Specifies whether to enable self-control power-on. (stateless computing configuration) |
Yes |
|
Stateless |
BroadcastNetSegment |
Specifies the broadcast network segment used for automatic discovery. (stateless computing configuration) |
Yes |
|
Stateless |
BroadcastPort |
Specifies the broadcast port number used for automatic discovery. (stateless computing configuration) |
Yes |
|
Stateless |
SysManagerIP |
Specifies the IP address of the server that performs power control. (stateless computing configuration) |
Yes |
|
Stateless |
SysManagerPort |
Specifies the port number of the server that performs power control. (stateless computing configuration) |
Yes |
|
USBMassStorage |
UmsMaxUpdateSpace |
Specifies the flag indicating that the component configuration or upgrade package is delivered to the NAND flash memory. |
Yes |
|
USBMassStorage |
SpConfigFileReady |
Specifies the mode for accessing the SP. |
Yes |
|
USBMassStorage |
SPStartmode |
Specifies the interval between the SP operation completion time and the OS reset time. |
Yes |
|
USBMassStorage |
SysRestartDelay |
Specifies the OS restart delay. |
Yes |
Parameter |
Description |
---|---|
ProcessorHyperThreadingDisable |
Specifies whether processor hyper-threading is enabled. |
ProcessorFlexibleRatioOverrideEnable |
Specifies whether the feature of setting the CPU frequency upper limit is enabled. This feature is disabled by default. |
ProcessorFlexibleRatio |
Specifies the CPU frequency upper limit. By default, it is the nominal CPU frequency. |
MonitorMwaitEnable |
Specifies whether Monitor/Mwait is enabled. |
ProcessorVmxEnable |
Specifies whether CPU virtualization is enabled. |
ProcessorLtsxEnable |
Specifies whether Intel TXT is enabled. |
MlcStreamerPrefetcherEnable |
Specifies whether hardware prefetcher is enabled. Before processing instructions or data, the CPU prefetches these instructions or data and saves them to the L2 cache. This reduces memory read time, eliminates potential bottlenecks, and therefore improves system performance. |
MlcSpatialPrefetcherEnable |
Specifies whether adjacent cache prefetcher is enabled. This feature allows prefetch of the data adjacent to the data to be read. This improves read speed significantly. |
DCUStreamerPrefetcherEnable |
Specifies whether DCU streamer prefetcher is enabled. This function allows CPU data to be prefetched, which reduces data read time. |
DCUIPPrefetcherEnable |
Specifies whether DCU IP prefetcher is enabled. This function enables the system to check historical records for the data that must be prefetched, which reduces data read time. |
CustomPowerPolicy |
Menu for selecting the energy-saving mode. It does not support customization. |
PowerSaving |
Indicates a Huawei-customized parameter for Dynamic Energy Management Technology (DEMT), integrates uniBIOS frequency adjustment algorithms developed by Huawei, and improves energy efficiency. |
ProcessorEistEnable |
Specifies whether Enhanced Intel SpeedStep® Technology (EIST) is enabled. EIST enables CPU frequency to be dynamically adjusted based on workloads, reducing heat dissipation. |
TurboMode |
Specifies whether CPU Turbo mode is enabled. |
PStateDomain |
PStateDomain switch. PStateDomain adjusts frequencies by core or package. |
ProcessorCcxEnable |
CPU C-state control menu, which controls the power consumption of CPUs in idle state. |
TStateEnable |
CPU T-state switch. This function is not available because it limits the CPU frequency. |
PackageCState |
Package C state setting. |
C3Enable |
CPU C3 state setting switch. |
C6Enable |
CPU C6 state setting switch. |
ProcessorC1eEnable |
CPU C1e state setting switch. |
OSCx |
ACPI C2/C3 adjustment |
QpiLinkSpeed |
QPI LINK Speed |
ClusterOnDieEn |
Memory Snoop mode ClusterOnDie setting switch |
EarlySnoopEn |
Memory Snoop mode EarlySnoop and HomeSnoop setting switch |
DdrFreqLimit |
Memory frequency setting switch. |
RankMargin |
Rank Margin Tool switch. |
rmtPatternLength |
RMT Pattern Length, which is set when Rank Margin Tool is enabled. |
MemTestOnFastBoot |
Memory test switch set for fast boot. |
ADREn |
Memory ADR switch |
CustomRefreshRateEn |
Memory refresh rate switch. |
CustomRefreshRate |
Specifies the memory refresh rate. |
refreshMode |
Specifies the memory refresh mode. 1 indicates 2x memory self-refresh, and 0 indicates that 2x memory self-refresh is not supported. If this parameter is set to 1, the memory refresh rate will be doubled when the memory DIMM exceeds 85ºC. |
mcODTOverride |
Memory mc on die termination (ODT) setting. ODT is a mechanism that allows the DRAM controller to dynamically control the termination resistance value of DQ/DQS/DM pins on DRAM devices in a variety of ways. The value can be 50 ohms or 100 ohms. |
NumaEn |
Non Uniform Memory Access (NUMA) is a distributed memory access mode. It allows reasonable memory allocation among multiple nodes and the processor to simultaneously access different memory addresses. |
IsocEn |
Specifies whether to enable the isochronous flow-control mode, which ensures the quality of traffic to/from PCH and impacts the memory performance because some bandwidths are reserved for DMI. |
RASMode |
Specifies the memory RAS mode. It can be independent mode, mirrored mode, or Lockstep mode. |
enableSparing |
Rank Sparing setting switch |
multiSparingRanks |
Haswell CPU supports multiple spare ranks. You can set the number of spare ranks for a channel. |
spareErrTh |
Memory correctable error threshold. When the number of correctable errors reaches this threshold, an SMI will be triggered and measures will be taken based on the RAS feature configured. |
PatrolScrub |
Controls the memory patrol scrub feature. The memory engine checks the memory at a certain speed and correct the correctable errors found, to prevent errors from being accumulated to uncorrectable errors. |
PatrolScrubDuration |
Specifies the memory patrol duration in hours. |
DemandScrubMode |
Controls the Demand Scrub feature. When HA reads memory data, it corrects errors found and writes correct data to the memory. |
DeviceTaggingMode |
Controls the Device Tagging feature. This feature allows an SMI to be triggered when the number of errors occurred on a memory chip exceeds the threshold. During the SMI processing, a parity chip can be used to replace the faulty chip. |
thermalthrottlingsupport |
Specifies the memory temperature adjustment mode. Closed Loop Thermal Throttling (CLTT) applies to DIMMs with temperature sensors. It allows dynamic memory adjustment based on the sensor temperature. Open Loop Thermal Throttling (OLTT) applies to DIMMs without temperature sensor. It allows static memory adjustment based on configuration. |
PcieAcpiHotPlugEnable |
Specifies whether to enable IIO PCI-E Hotplug. |
EnableAzaliaVCpOptimizationste |
Specifies whether to enable azalia_on_vcp. |
PCIeSRIOVSupport |
Specifies whether to enable PCIe virtualization function. |
VTdSupport |
Specifies whether to enable Intel VT for Directed I/O (VT-d). |
InterruptRemap |
Specifies whether to enable Interrupt Remapping, which is related to VT-d. |
CoherencySupport |
Specifies whether to enable Coherency Support, which is related to VT-d. |
IsochCoherencySupport |
Specifies whether to enable Coherency Support (Isoch), which is related to VT-d. |
IdeController |
Specifies whether to enable SATA controller. |
SataCnfigure |
Specifies the SATA controller mode. |
PchsSata |
Specifies whether to enable sSATA controller. |
sSataInterfaceMode |
Specifies the sSATA controller mode. |
XHCIMode |
Specifies the USB 3.0 controller switch. |
CREnable |
Serial port redirection switch. |
CRTerminalType |
Font type selection switch for serial port redirection. |
CRBaudRate |
Baud Rate selection switch for serial port redirection. |
CRInfoWaitTime |
Initialization information display time for serial port redirection. |
CRAfterPost |
Specifies whether serial port redirection takes effect after BIOS POST. |
PXE1setting |
LOM 1 PXE switch |
PXE2setting |
LOM 2 PXE switch |
WheaSupport |
Specifies whether to enable WHEA for fault diagnosis. |
WheaEinjType |
Specifies whether to enable WHEA error injection for fault diagnosis. |
SystemErrorEn |
Specifies whether to enable fault diagnosis. |
FDM |
Specifies whether to enable reporting of fault diagnosis to the BMC. |
PoisonEn |
Poison bit switch. |
EMcaLogEn |
EMCA log (ELOG) switch. The BIOS creates ELOG entries, which record error information in detail for the OS/VMM to predict faults. The log is stored in the reserved memory provided by the BIOS and accessed through the Entry address. There is also a WHEA log corresponding to ELOG, and the structure of the WHEA log is defined by ACPI specifications. |
EMcaCSmiEn |
CMCI-to-SMI signal switch. If it is disabled, only CMCI will be triggered when correctable errors are found on the memory. An SMI will be triggered only when the number of errors reaches the threshold. If it is enabled, each correctable error will trigger an SMI, which is processed by the BIOS. At the end of the SMI processing function, the BIOS decides whether to send an MCE signal to the OS. This helps to collect more useful information. |
PowerStateRestoreOnACLoss |
Specifies the power control policy for the operating system when the AC is powered on.
|
BmcWdtEnable |
Specifies whether to enable the POST watch dog. |
BmcWdtTimeout |
Specifies the timeout period of the POST watch dog. |
BmcWdtAction |
Specifies the POST watch dog actions. |
OSWdtEnable |
Specifies whether to enable the OS watch dog. |
OSWdtTimeout |
Specifies the timeout period of the OS watch dog. |
OSWdtAction |
Specifies the OS watch dog actions. |
SysDbgLevel |
BIOS debugging switch |
serialDebugMsgLvl |
BISO debugging print level. |
Pci64BitResourceAllocation |
If this function is enabled, the PCI MMIO address space is greater than 4 GB. |
ClkGenSpreadSpectrum |
Spread spectrum switch. |
WakeOnPME |
Wake On LAN switch. |
NICTrunk |
Before OS starts, the DisableNic2ndhandle function will be called to disable the second optical port of 82599. This function is not available at present. |
Language |
Specifies the language used. |
ComBaseOutput |
Serial port IO base settings. |
OemMemTurbo |
Memory overclock switch. |
SoftRaidModeSelect |
SoftRAID selection switch. NOTE:
V5 servers do not support this configuration. |
BootType |
Specifies the boot type, which can be Legacy, UEFI, or DUAL. |
QuickBoot |
Quick Boot settings. If it is disabled, a memory test will be performed after the first screen after each start. |
QuietBoot |
Specifies whether to display boot information before the BIOS logo appears. |
PXEOnly |
Specifies whether to limit the server to boot from PXE only and skip other boot options (such as a hard disk and CD-ROM). |
VideoSelected |
Onboard video card or external video card |
NoBootDevCtr |
Specifies whether the board is automatically restarted when no boot device is available. |
BootTypeOrder[0] |
Specifies the boot sequence. |
BootTypeOrder[1] |
Specifies the boot sequence. |
BootTypeOrder[2] |
Specifies the boot sequence. |
BootTypeOrder[3] |
Specifies the boot sequence. |
Type |
Export Parameter |
Export Subparameter |
Description |
Valid After Imported via Configuration File |
---|---|---|---|---|
Storage |
RaidController |
Type |
Specifies the controller type. |
No The value is displayed in the configuration file. |
RaidController |
CopybackEnabled |
Specifies the copyback function status of the RAID controller card. |
Yes |
|
RaidController |
SMARTerCopybackEnabled |
Specifies whether to automatically perform copyback when the RAID controller card detects a physical disk SMART error. |
Yes |
|
RaidController |
JBODEnabled |
Specifies the JBOD function status of the RAID controller card. |
Yes |