Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Logging In to U-Boot

Logging In to U-Boot

Scenarios

Log in to U-Boot of the iBMC over a serial port.

U-Boot commands are used to load underlying software and debug underlying devices. Only qualified maintenance engineers can use U-Boot commands.

Prerequisites

  • User name and password for logging in to the iBMC

    The default user is root for V3 servers and Administrator for V5 servers, and the default password is on the product nameplate.

  • Password for logging in to the iBMC U-Boot

    The default password is Huawei12#$ for V3 servers and Admin@9000 for V5 servers.

For security purposes, change the initial password after the first login and change your password periodically.

Procedure

  1. Log in to the iBMC CLI over the serial port.

  2. Restart the iBMC.

    iBMC:/->ipmcset –d reset
    This operation will reboot iBMC system. Continue? [Y/N]:

  3. Type Y and press Enter.

    The iBMC restarts.

  4. Press Ctrl+B when the message Hit 'ctrl + b' to stop autoboot: is displayed.

    The output is as follows:

    ENTER PASSWD:

  5. Enter the password for logging in to U-Boot.The default password is Huawei12#$ for V3 servers and Admin@9000 for V5 servers.

    The U-Boot CLI is displayed.