Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting a Dead Time for a Neighbor Relationship

Setting a Dead Time for a Neighbor Relationship

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface interface-type interface-number

    The OSPF interface view is displayed.

  3. Run ospf timer dead interval

    A dead time after which the neighbor relationship expires between two switches is set.

    By default, the dead time is 40s on a P2P or broadcast interface and 120s on a P2MP or NBMA interface. The dead time is four times the interval for sending Hello packets on the same interface.

    NOTE:

    A dead time longer than 20s is recommended. If the dead time is shorter than 20s, the OSPF neighbor relationship may be disconnected unexpectedly.

    Both the Hello timer and the Dead timer are restored to their default values upon a change to the network type.