No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

S600-E V200R011C10 NETCONF YANG API Reference

This document describes the NETCONF API functions supported by the switch, including the data model and samples.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Data Model

Data Model

The configuration model file matching performance reporting is huawei-system-performance.yang.

Table 2-10  Performance reporting

Object

Description

Value Range

Remarks

/huawei-system-performance:pm-config/server-connection-parameters/name

Indicates the connection name.

The value is a character string.

NA

/huawei-system-performance:pm-config/server-connection-parameters/server-url

Indicates the server IP address.

The value is a character string.

/huawei-system-performance:pm-config/server-connection-parameters/server-port

Indicates the server port.

The value is an integer that ranges from 0 to 65535.

/huawei-system-performance:pm-config/server-connection-parameters/collection-polices/default-upload-interval

Indicates the interval for reporting performance data.

The value is an integer that ranges from 1 to 1440.

/huawei-system-performance:pm-config/server-connection-parameters/connection-policies/heartbeat-interval

Indicates the heartbeat interval for the connection with the server.

The value is an integer that ranges from 5 to 60.

/huawei-system-performance:pm-config/collection-item-policy/policies/name

Indicates the policy name.

The value is a character string.

/huawei-system-performance:pm-config/collection-item-policy/data-collection-item/type

Indicates the type of collected performance data.

Enumerated value:
  • performance-data
  • station-data
  • application-data
  • log-data
  • location-data
  • security-data
  • terminal-identification-data
NOTE:

The switch only supports performance-data.

/huawei-system-performance:pm-config/collection-item-policy/data-collection-item/collection-enable

Indicates whether performance data collection is enabled.

The value is of the Boolean type:
  • true: Performance data collection is enabled.

  • false: Performance data collection is disabled.

/huawei-system-performance:pm-config/collection-item-policy/data-collection-item/item-collection-interval

Indicates the interval at which the system collects performance data.

The value is an integer that ranges from 1 to 1440.

Translation
Download
Updated: 2019-03-30

Document ID: EDOC1000178028

Views: 4335

Downloads: 0

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next