S12700 V200R011C10 Configuration Guide - Network Management and Monitoring

This document provides the configurations of network management and monitoring features supported by the product, including SNMP, RMON and RMON2, LLDP, Performance Management, iPCA, NQA, Service Diagnosis, Mirroring, Packet Capture, Traffic Distribution, NetStream, sFlow, and TWAMP Light.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring a Path Jitter Test

Configuring a Path Jitter Test

Context

The communication data between two devices on a network may need to traverse other devices. To fully monitor a network, you can configure path jitter test.

Perform the following configurations on the NQA client:

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run nqa test-instance admin-name test-name

    An NQA test instance is created and the test instance view is displayed.

  3. Run test-type pathjitter

    The test type is set to path jitter.

  4. Run destination-address ipv4 ipv4-address

    The destination address is configured.

  5. (Optional) Run the following commands to set other parameters for the path jitter test:

    • To configure description for the test instance, run the description string command.

    • To set the test interval, run the frequency interval command.

    • To set the timeout period for a probe in an NQA test instance, run the timeout time command.

    • To set the Type of Service (ToS) for the test instance, run the tos value command.

    • To set the maximum number of historical records, run the records history number command.

    • To set the maximum number of test results that can be recorded, run the records result number command.
    • To set the aging time of the test instance, run the agetime hh:mm:ss command.

    • To set the test mode of the path jitter test, run the icmp-jitter-mode { icmp-echo | icmp-timestamp } command.

      By default, the test mode is icmp-timestamp.

      NOTE:

      The datafill and datasize parameters are valid only when the icmp-jitter-mode is set to icmp-echo.

    • To configure the pad characters, run the datafill fillstring command.

    • To set the size of Echo Request packets excluding the IP header, run the datasize size command.

    • Run vpn-instance vpn-instance-name

      The VPN instance name is configured.

    • To configure the source IP address, run the source-address ipv4 ipv4-address command.

    • To set the number of probes sent each time, run the probe-count number command.

    • To set the number of test packets sent during each test, run the jitter-packetnum number command.

      NOTE:

      The probe-count command sets the number of path jitter tests and the jitter-packetnum command sets the number of test packets sent during each test. The value of probe-count multiplied by the value of jitter-packetnum cannot exceed 3000.

    • To set an interval for sending test packets, run the interval { milliseconds interval | seconds interval } command.

      The shorter the interval is, the sooner the test is completed. Generally, the CPU has a delay in sending and receiving test packets. Therefore, an excessively short interval will make the test statistics inaccurate.

    • To set the percentage of the failed NQA test instances, run the fail-percent percent command.