Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Observing Port Specifications

Observing Port Specifications

  • Configuration Modes

    In V200R005 and later versions, there are two modes for configuring observing ports: single configuration and batch configuration. Both modes can be used simultaneously. If multiple observing ports are configured in a batch, these observing ports are bound to the same mirrored port. Therefore, batch configuration simplifies the configuration of 1:N mirroring. Figure 8-5 shows batch configuration of observing ports.

    Figure 8-5  Configuring observing ports in a batch
  • Calculating the Number of Available Observing Ports

    The number of available observing ports depends on the total number of observing ports to which mirrored ports have been bound in the inbound and outbound directions. The number of observing ports to which a mirrored port is bound in the inbound direction is calculated separately to those bound in the outbound direction. When the same observing port is bound to the mirrored port in both the inbound and outbound directions, the numbers of available observing ports for inbound and outbound packets are both reduced by 1.

    As shown in Figure 8-6, a maximum of six observing ports can be configured on E series cards (except ET1D2X48SEC0). Inbound packets on all the mirrored ports can be copied and sent to a maximum of four observing ports, and outbound packets can be copied and sent to a maximum of two observing ports. If inbound and outbound packets on the mirrored ports are copied and sent to the same observing port, the numbers of available observing ports for inbound and outbound packets are 3 and 1 respectively. Therefore, the total number of available observing ports is 4 (3 plus 1) but not 5 (6 minus 1).

    Figure 8-6  Usage of observing ports

  • Specifications

    Table 8-2 lists the observing port specifications for different series cards.

    NOTE:

    You can configure a maximum of eight observing ports on a device, excluding the observing ports configured in a batch on X series cards.

    Table 8-2  Observing port specifications for different series of cards
    Card Total Number of Observing Ports to Which All Mirrored Ports Can Be Bound in the Inbound Direction Total Number of Observing Ports to Which All Mirrored Ports Can Be Bound in the Outbound Direction Maximum Observing Ports Supported per Device
    ET1D2X12SSA0 4 2 6
    SC series cards X (X ≤ 4) 4-X (X ≤ 4) 4
    E series cards, except ET1D2X48SEC0 and ET1D2C02FEE0 4 2 6
    ET1D2X48SEC0 and ET1D2C02FEE0 X (X ≤ 4) 4-X (X ≤ 4) 4
    X series cards
    • A maximum of 64 observing ports can be configured in a batch, and you can configure a maximum of eight batches. Theoretically, mirrored ports can be bound to a maximum of 512 (8 x 64) observing ports in the inbound direction.
    • If one observing port is configured each time, the observing port configuration can be performed a maximum of eight times, and mirrored ports can be bound to a maximum of eight observing ports in the inbound direction.
    • When single configuration and batch configuration are both used, the observing port configuration can be performed a maximum of eight times, and the maximum number of observing ports to which mirrored ports can be bound in the inbound direction ranges between 8 and 512.
    • A maximum of 64 observing ports can be configured in a batch, and you can configure a maximum of eight batches. Theoretically, mirrored ports can be bound to a maximum of 512 (8 x 64) observing ports in the outbound direction.
    • If one observing port is configured each time, the observing port configuration can be performed a maximum of eight times, and mirrored ports can be bound to a maximum of eight observing ports in the outbound direction.
    • When single configuration and batch configuration are both used, the observing port configuration can be performed a maximum of eight times, and the maximum number of observing ports to which mirrored ports can be bound in the outbound direction ranges between 8 and 512.
    • A maximum of 64 observing ports can be configured in a batch, and you can configure a maximum of eight batches. Theoretically, a maximum of 512 (8 x 64) observing ports can be configured.
    • If one observing port is configured each time, the observing port configuration can be performed a maximum of eight times, and a maximum of eight observing ports can be configured.
    • When single configuration and batch configuration are both used, the observing port configuration can be performed a maximum of eight times, and the maximum number of observing ports ranges between 8 and 512.