No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwCfgOperateTable

hwCfgOperateTable

The table is an operation table, providing the operation mode through network management.

The index of the table is hwCfgOperateIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.10.1.2.4.1.1

hwCfgOperateIndex

Integer32 (1..2147483647)

Not-accessible

The value of this object identifies operation.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.10.1.2.4.1.2

hwCfgOperateType

ConfigOperationType

Read-create

The value of the object identifies the operation type.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.10.1.2.4.1.3

hwCfgOperateProtocol

INTEGER{ftp(1)tftp(2)sftp(3)}

Read-create

The value of the object identifies the used protocol.

FTP or TFTP is insecure. Therefore, configuring SFTP is recommended.

This object is implemented as defined in the corresponding MIB files.

When this object is set to sftp(3), only a password can be used for authentication. If a public key is used, the authentication fails.

1.3.6.1.4.1.2011.6.10.1.2.4.1.4

hwCfgOperateFileName

DisplayString (SIZE (1..128))

Read-create

The object indicates the file name.

  • If the file name does not contain any path, the file name length is 1 to 64 bytes.
  • If the file name contains a path, the file name length is 1 to 128 bytes.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.10.1.2.4.1.5

hwCfgOperateServerAddress

IpAddress

Read-create

The object indicates the address of the server.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.10.1.2.4.1.6

hwCfgOperateUserName

DisplayString (SIZE (1..40))

Read-create

The object indicates the FTP user name.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.10.1.2.4.1.7

hwCfgOperateUserPassword

DisplayString (SIZE (0..40))

Read-create

The object indicates the FTP user password.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.10.1.2.4.1.8

hwCfgOperateEndNotificationSwitch

TruthValue

Read-create

The object indicates whether the Trap message is sent when the operation is complete.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.10.1.2.4.1.9

hwCfgOperateRowStatus

RowStatus

Read-create

The object indicates the status of the operation row.

When the status is Active, the following situations occur:

  • If the mapping instance is transmitted through FTP/TFTP, the transmission can be aborted by setting the current status as notInService.
  • In other cases, the transmission of the instance cannot be aborted even the status is set to notInService.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.10.1.2.4.1.10

hwCfgOperateServerPort

Integer32(1..65535)

Read-create

The value of the object identifies the number of the listening port on the FTP/SFTP server:
  • The default listening port number of an SFTP server is 22.
  • The default listening port number of an FTP server is 21.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.10.1.2.4.1.11

hwCfgOperateSourceAddress

IpAddress

Read-create

This object indicates the source IP address.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.10.1.2.4.1.12

hwCfgOperateSourceInterface

OCTET STRING(SIZE (1..47))

Read-create

This object indicates the source interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.10.1.2.4.1.13

hwCfgOperateOnError

INTEGER

{

continueOnError(1),

stopOnError(2),

rollbackOnError(3)

}

read-create

The value of the object identifies the follow-up operation if a command fails to be run.
  • continueOnError: The system ignores the command that fails to be run and proceeds to run the next command.

  • stopOnError: The system no longer runs following commands.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.10.1.2.4.1.17

hwCfgOperateServerAddressType

InetAddressType

read-create

This object identifies the type of an IP address that an FTP, TFTP, or SFTP server uses.
  • 1: IPv4 address
  • 2: IPv6 address

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.6.10.1.2.4.1.18

hwCfgOperateServerAddressNet

InetAddress

read-create

This object identifies an IP address that an FTP, TFTP, or SFTP server uses or a host name.

Currently, the bject does not support IPv4 addresses.

1.3.6.1.4.1.2011.6.10.1.2.4.1.19

hwCfgOperateVpnInstance

DisplayString (SIZE (0..31))

read-create

This object indicates the VPN instance name that through which to transfer the file.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

The following entries can be created:

  • hwCfgOperateType

  • hwCfgOperateProtocol

  • hwCfgOperateFileName

  • hwCfgOperateServerAddress

  • hwCfgOperateUserName

  • hwCfgOperateUserPassword

  • hwCfgOperateEndNotificationSwitch

  • hwCfgOperateRowStatus

  • hwCfgOperateServerPort

  • hwCfgOperateSourceAddress

  • hwCfgOperateSourceInterface

Modification Restriction

The following entries can be modified:

  • hwCfgOperateType

  • hwCfgOperateProtocol

  • hwCfgOperateFileName

  • hwCfgOperateServerAddress

  • hwCfgOperateUserName

  • hwCfgOperateUserPassword

  • hwCfgOperateEndNotificationSwitch

  • hwCfgOperateRowStatus

Deletion Restriction

The following entries can be deleted:

  • hwCfgOperateType

  • hwCfgOperateProtocol

  • hwCfgOperateFileName

  • hwCfgOperateServerAddress

  • hwCfgOperateUserName

  • hwCfgOperateUserPassword

  • hwCfgOperateEndNotificationSwitch

  • hwCfgOperateRowStatus

Access Restriction

The following entries can be read:

  • hwCfgOperateType

  • hwCfgOperateProtocol

  • hwCfgOperateFileName

  • hwCfgOperateServerAddress

  • hwCfgOperateUserName

  • hwCfgOperateUserPassword

  • hwCfgOperateEndNotificationSwitch

  • hwCfgOperateRowStatus

Translation