S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwSvcExtTable

hwSvcExtTable

This table is an SVC extended configuration table. It allows you to query, create, and delete SVCs. Currently, only the query function is available.

The indexes of this table are hwSvcExtIfIndex and hwSvcExtPWType.

OID

Object Name

Data Type

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.1

hwSvcExtIfIndex

InterfaceIndexOrZero

Not-accessible

This object indicates the index of an interface associated with a PW.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.2

hwSvcExtPWType

HWL2VpnVcType

not-accessible

This object indicates the SVC type.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.3

hwSvcExtID

Unsigned32

Read-create

The value of this object identifies the VC ID.

The maximum access to this object is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.4

hwSvcExtType

HWL2VpnVcEncapsType

Read-create

This object indicates the encapsulation type of a PW. For specific encapsulation types, see hwPwVcType.

The maximum access to this object is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.5

hwSvcExtPeerAddrType

InetAddressType

Read-create

This object indicates the peer IP address type.

The maximum access to this object is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.6

hwSvcExtPeerAddr

IpAddress

Read-create

This object indicates the peer IP address of the SVC. If the type of hwSvcPeerAddrType is unknown, the peer IP address of the SVC is all 0s.

The maximum access to this object is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.7

hwSvcExtStatus

Integer

{

  • Up
  • Down
  • Plugout

}

Read-only

The value of this object identifies the SVC status of the local node:
  • 1: Up
  • 2: Down
  • 3: Plugout

Currently, Plugout is not supported.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.8

hwSvcExtInboundLabel

Unsigned32

Read-create

The value of this object identifies the in-label for the SVC.

The maximum access to this object is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.9

hwSvcExtOutboundLabel

Unsigned32

Read-create

The value of this object identifies the out-label for the SVC.

The maximum access to this object is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.10

hwSvcExtAcStatus

INTEGER:

{
  • up(1)
  • down(2)
  • plugout(3)

}

Read-only

This object indicates the physical status of an AC interface:
  • 1: Up
  • 2: Down
  • 3: Plugout

Currently, Plugout is not supported.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.12

hwSvcExtCtrlWord

HWEnableValue

Read-create

This object indicates the control word capability:
  • 1: enabled
  • 2: disabled

The maximum access to this object is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.13

hwSvcExtVCCV

BITS:

{
  • ccCw(0)
  • ccAlert(1)
  • ccLabel(2)
  • cvIcmpping(3)
  • cvLspping(4)
  • cvBfd(5)

}

Read-create

This object indicates optional VCCV capabilities.

By default, the values are ccAlert(1), cvLspping(4), and cvBfd(5).

The maximum access to this object is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.15

hwSvcExtTnlPolicyName

OCTET STRING (SIZE (0..39))

Read-create

This object indicates the name of a tunnel policy. If not specified, the default tunnel policy name length is 0.

The maximum access to this object is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.16

hwSvcExtPWTemplateName

OCTET STRING (SIZE (0..19))

Read-create

This object indicates the name of a PW template. If not specified, the default value is 0.

The maximum access to this object is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.17

hwSvcExtUpTime

Unsigned32

Read-only

The value of this object identifies the latest total Up time of the SVC.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.27

hwSvcExtUpStartTime

DisplayString (SIZE (0..63))

Read-only

This object indicates the time when the PW was restored the last time.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.28

hwSvcExtUpSumTime

Unsigned32

Read-only

The value of this object identifies the total Up time of the SVC, in seconds.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.34

hwSvcExtRawOrTagged

INTEGER:

{

  • raw(1)
  • tagged(2)
  • rawTagNotConfiged(3)

}

Read-create

The value of this object identifies whether the tagged flag is carried.

The maximum access to this object is read-only.

1.3.6.1.4.1.2011.5.25.119.4.1.3.8.1.36

hwSvcExtRowStatus

RowStatus

Read-create

This object indicates the row status.

The maximum access to this object is read-only.

Creation Restriction

None

Modification Restriction

None

Deletion Restriction

None

Access Restriction

None

Translation