Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwAPSpecificWiredPortTable

hwAPSpecificWiredPortTable

This table is used to bind an AP wired port profile to an AP or unbind an AP wired port profile from an AP.

Indexes of this table are hwAPSpWPInterfaceType, hwAPSpWPInterfaceNum, and hwAPSpApMac.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.139.11.1.8.1.1

hwAPSpWPInterfaceType

INTEGER{fe(1),ge(2),trunk(3),multige(4)}

not-accessible

This object indicates the interface type.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.8.1.2

hwAPSpWPInterfaceNum

Unsigned32(0–27)

not-accessible

This object indicates the interface index.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.8.1.3

hwAPSpWPProfile

OCTET STRING(1–35)

read-write

This object indicates the bound wired port profile.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.8.1.4

hwAPSpWPRowStatus

RowStatus{active(1),notInService(2),notReady(3),createAndGo(4),createAndWait(5),destroy(6)}

read-write

This object indicates the row status. createAndGo(4) and destroy(6) are mainly used.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.8.1.5

hwAPSpWPApId

Unsigned32

read-only

AP ID.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

When creating an entry in this table, specify the hwAPSpWPInterfaceType, hwAPSpWPInterfaceNum, and hwAPSpApMac indexes, as well as the hwAPSpWPRowStatus and hwAPSpWPProfile nodes. hwAPSpWPInterfaceType and hwAPSpWPInterfaceNum indicate the type and index of the interface to be bound. hwAPSpWPProfile indicates the name of the wired port profile to be bound. You can bind this table to an AP when the hwAPSpWPRowStatus value is createAndGo(4).

Modification Restriction

The entries in this table can be modified without restriction.

Deletion Restriction

When deleting an entry in this table, specify the hwAPSpWPInterfaceType, hwAPSpWPInterfaceNum, and hwAPSpApMac indexes, as well as the hwAPSpWPRowStatus and hwAPSpWPProfile nodes. hwAPSpWPInterfaceType and hwAPSpWPInterfaceNum indicate the type and index of the interface to be unbound. hwAPSpWPProfile indicates the name of the wired port profile to be unbound. You can unbind this table from an AP when the hwAPSpWPRowStatus value is destroy (6).

Access Restriction

The entries in this table can be read only when the corresponding AP exists.