No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwPWTemplateTable

hwPWTemplateTable

This table is a PW template configuration table. You can create and delete a PW template by using this table. Now the entries in this table can be queried only.

The index of this table is hwPwTemplateName.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.119.4.1.5.1.1

hwPWTemplateName

Octet String(size(0..19))

Not-accessible

This object indicates the name of the PW template.

The name is a case-sensitive string of 0 to 19 characters. If not specified, the default value of the object is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.5.1.2

hwPWTemplatePeerAddrType

InetAddressType

Read-create

The value of this object specifies the type of the peer IP address.

  • 0: unknown type
  • 1: IPv4 address
  • 2: IPv6 address
  • 3: IPV4z address
  • 4: IPV6z address
  • 16: DNS

Currently, the maximum access is read-only;

At present, this object supports only IPv4 addresses. Besides, if the protocol type of the PW is unknown, the value of this object is also unknown.

1.3.6.1.4.1.2011.5.25.119.4.1.5.1.3

hwPWTemplatePeerAddr

IpAddress

Read-create

The object indicates the peer IP address of the PW.

If the value is all 0s, the specified peer IP address of the PW is deleted from the PW template.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.5.1.4

hwPWTemplateCtrlword

HWEnableValue

Read-create

The value of this object identifies the capability of control word.

  • 1: true (enable)
  • 2: false (disable)

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.5.1.5

hwPWTemplateVCCV

BITS{ccCw(0),ccAlert(1),ccLabel(2),cvIcmpping(3),cvLspping(4),cvBfd(5),ccTtl(6)}

Read-create

This object indicates the optional VCCV capabilities of the PW template. According to whether the control word is enabled, the value can be ccCw(0)|ccAlert(1)|ccTtl(6)|cvLspping(4)|cvBfd(5) or ccAlert(1)|ccTtl(6)|cvLspping(4)|cvBfd(5). The default value is ccAlert(1)|ccTtl(6)|cvLspping(4)|cvBfd(5).

  • 0: control channel of the control word (ccCw)
  • 1: control channel of the MPLS router alert (ccAlert)
  • 4: LSP ping connectivity verification (cvLspping)
  • 5: BFD connectivity verification (cvBfd)
  • 6: control channel of the time to live (ccTtl)

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.5.1.8

hwPWTemplateTnlPolicyName

Octet String(size(0..39))

Read-create

This object indicates the name of the tunnel policy.

The name is a string of 0 to 19 characters.

By default, the length of the name is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.5.1.11

hwPWTemplateBfdDetectMultiplier

Unsigned32(0|3–50)

Read-create

This object indicates the local BFD detection multiple. The value of the object ranges from 3 to 50.

When the BFD detect function is not enabled in the PW template, the value of the object is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.5.1.12

hwPWTemplateBfdMinReceiveInterval

Unsigned32(0|10~1000)

Read-create

This object indicates the interval to receive BFD packets. The value of the object ranges from 10 to 1000, expressed in milliseconds. When the BFD detect function is not enabled in the PW template, the value of the object is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.5.1.13

hwPWTemplateBfdMinTransmitInterval

Unsigned32(0|10~1000)

Read-create

This object indicates the interval to send BFD packets. The value of the object ranges from 10 to 1000, expressed in milliseconds. When the BFD detect function is not enabled in the PW template, the value of the object is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.5.1.14

hwPWTemplateDynamicBfdDetect

TruthValue

Read-create

The value of this object identifies whether the dynamic BFD for PW is supported.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.5.1.19

hwPWTemplatePwIdleCode

Unsigned32 (0..255 | 65535)

Read-create

This object indicates the value of an idle code. The value is a hexadecimal number ranging from 0x00 to 0xFF. The default value is 0xFF and the invalid value is 0xFFFF.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.4.1.5.1.51

hwPWTemplateRowStatus

RowStatus

Read-create

This object indicates the row status of this table.

Restriction:

To create this table, you must adopt the CreatAndGo processing mode, rather than the CreatAndWait processing mode.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

None.

Modification Restriction

The entries in this table can be modified.

  • The hwPWTemplateBFDDetectMultiplier, hwPWTemplateBFDMinReceiveInterval, and hwPWTemplateBFDMinTransmitInterval must be used together with the hwPWTemplateDynamicBFDDetect.
  • The hwPWTemplatePwCCSeqEnable can be used only after the hwPWTemplateCtrlword is configured.

Deletion Restriction

None.

Access Restriction

None.

Translation
Download
Updated: 2019-03-29

Document ID: EDOC1000178122

Views: 678165

Downloads: 34

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next