S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwMplsPsTable

hwMplsPsTable

hwMplsPs table describes features of the protection group. It is used to:

  • Check all the parameters, including the names of and the IDs of the active and standby tunnels, switch-back mode, WTR time, and the Holdoff time required by the protection group.

  • Check the protection switch status, including the status of the active and standby tunnels and the switch result

The index of this table is hwMplsPsIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.1

hwMplsPsIndex

Unsigned32

Read-only

The value of this object identifies the index of the active tunnel interface

Value range: 1 to 4294967296

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.2

hwMplsPsType

Integer32

Read-only

The value of this object identifies the protection type.

Values are as follows:
  • 1: 1:1
  • 2: 1+1
  • 3: shared mesh
  • 4: packet 1+1
Currently, only 1:1 is supported.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.3

hwMplsPsWorkTunnName

OCTET STRING

Read-only

This object indicates the active tunnel.

The string must be of no more than 16 bytes.

There is no default value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.4

hwMplsPsWorkTunnId

Integer32

Read-only

The value of this object identifies the active tunnel ID.

Value range: 1 to 65535

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.5

hwMplsPsProtectTunnName

OCTET STRING

Read-only

This object indicates the name of the standby tunnel.

The string must be of no more than 16 bytes.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.6

hwMplsPsProtectTunnId

Integer32

Read-only

The value of this object identifies the standby tunnel ID.

Value range: 1 to 65535

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.7

hwMplsPsRevertiveMode

Integer32

Read-only

The value of this object identifies the switch-back mode.

Values are as follows:
  • 1: Can switch-back
  • 2: Cannot switch-back

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.8

hwMplsPsWTR

Integer32

Read-only

The value of this object identifies the WTR time.

Value range: 0 to 60, Step length: 30s

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.9

hwMplsPsHoldOff

Integer32

Read-only

The value of this object identifies the Holdoff time

Value range:0 to 100

Step length: 100 ms

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.10

hwMplsPsSwitchCondition

Integer32

Read-only

The value of this object identifies the present function protection command.

Values are as follows:
  • 1: clear
  • 2: lockout of protection
  • 3: forced protection
  • 4: signal fail
  • 5: manual switch for working-lsp
  • 6: manual switch for protection-lsp
  • 7: WTR-timer
  • 8: Holdoff-timer
  • 9: others
There is no default value.
Currently, the following values are not supported:
  • 4: signal fail
  • 7: WTR-timer
  • 8: Holdoff-timer

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.11

hwMplsPsWorkTunnelState

Integer32

Read-only

The value of this object identifies the active tunnel status.

Values are as follows:
  • 1: indefective
  • 2: defective
There is no default value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.12

hwMplsPsProtTunnelState

Integer32

Read-only

The value of this object identifies the standby tunnel status.

Values are as follows:
  • 1: indefective
  • 2: defective
There is no default value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.13

hwMplsPsSwitchResult

Integer32

Read-only

The value of this object identifies the present switch result.

Values are as follows:
  • 1: indicates that the active tunnel is in operation.
  • 2: indicates that the standby tunnel is in operation.
There is no default value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.14

hwMplsPsCfgType

Integer32

Read-only

The value of this object identifies the type of configured protection groups. The configuration takes effect after commit.

Values are as follows:
  • 1: 1:1
  • 2: 1+1
  • 3: shared mesh
  • 4: packet 1+1
Currently, only 1:1 is supported.

There is no default value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.15

hwMplsPsCfgProtectTunnId

Integer32

Read-only

The value of this object identifies the configured standby Tunnel ID. The configuration takes effect after commit.

Value range: 1 to 65535

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.16

hwMplsPsCfgRevertiveMode

Integer32

Read-only

The value of this object identifies the configured switch-back mode. The configuration takes effect after commit.

Values are as follows:
  • 1: can switch back
  • 2: cannot switch back
Default value: 1

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.17

hwMplsPsCfgWTR

Integer32

Read-only

The value of this object identifies the configured WTR time. The configuration takes effect after commit.

Value range: 1 to 60

Step length: 30s

Default value: 720s

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.18

hwMplsPsCfgHoldOff

Integer32

Read-only

The value of this object identifies the configured Holdoff time. The configuration takes effect after commit.

Value range:0 to 100

Step length: 100ms

Default value: 0ms

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.19

hwMplsPsRowStatus

Row Status

Read-create

This object indicates the operating status of rows.

Values are as follows:
  • 1:active
  • 2:not in service
  • 3:not ready
  • 4:create and go
  • 5:create and wait
  • 6:destroy
There is no default value.
Currently, only the following operation modes are supported:
  • 1: active

  • 4: create and go

  • 6: destroy

1.3.6.1.4.1.2011.5.12.7.1.3.1.1.20

hwMplsPsLocalState

SYNTAX Integer32 (0..11)

read-only

The current local state of the protection group.

Values are as follows:
  • 0: Lockout of Protection (LO)
  • 1: Signal Fail for Protection (SF-P)
  • 2: Forced Switch (FS)
  • 3: Signal Fail for Working (SF)
  • 4: Signal Degrade for Protection(SD-P)
  • 5: Signal Degrade for Working(SD)
  • 6: Manual Switch (MS)
  • 7: Wait-to-Restore (WTR)
  • 8: Exercise (EXER)
  • 9: Reverse Request(RR)
  • 10: Do Not Revert (DNR)
  • 11: No Request (NR)

The priorities of the commands are as follows:

LO-> SF-P->FS->SF->SD-P->SD->MS->WTR->EXER->RR->DNR->NR

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

None.

Translation
Download
Updated: 2019-03-29

Document ID: EDOC1000178122

Views: 763143

Downloads: 36

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next