S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwLocalUserPwPolicyAcc

hwLocalUserPwPolicyAcc

The hwLocalUserPwPolicyAcc is used to create, set, and delete the password policy of the local access users.

NOTE:
This table does not support multi-node combination configuration.

OID

Object Name

Syntax

Implemented Specifications

Description

Status

1.3.6.1.4.1.2011.5.2.1.60.1.1

hwAccEnable

INTEGER

read-write

Indicates whether the password control function is enabled:
  • 0: The password control function is disabled.
  • 1: The password control function is enabled.

current

1.3.6.1.4.1.2011.5.2.1.60.1.2

hwAccPwHistoryRecordNum

Integer32

read-write

Indicates the maximum number of historical passwords recorded on the device.

current

Creation Restriction

None

Modification Restriction

None

Deletion Restriction

None

Access Restriction

None