S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwWlanVlanPoolTable

hwWlanVlanPoolTable

This table is used to configure VLAN pools.

The index of this table is hwVlanPoolName.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.139.11.1.25.1.1

hwVlanPoolName

OCTET STRING(1–31)

not-accessible

This object indicates the VLAN pool name. It is the index of the table.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.25.1.2

hwVlanPoolVlanlist

OCTET STRING(1–640)

read-write

This object indicates the VLAN list.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.25.1.3

hwVlanPoolAssignMethod

INTEGER{hash(1),even(2)}

read-write

This object indicates the VLAN pool allocation algorithm. The default value is 1.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.25.1.4

hwVlanPoolRowStatus

RowStatus{active(1),notInService(2),notReady(3),createAndGo(4),createAndWait(5),destroy(6)}

read-write

This object indicates the row status. createAndGo(4) and destroy(6) are mainly used.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

When creating entries, you must set hwVlanPoolName, hwVlanPoolRowStatus, and hwVlanPoolRowStatus to createAndGo(4).

Modification Restriction

The entries in this table can be modified without restriction.

Deletion Restriction

The entries in this table can be deleted without restriction.

Access Restriction

The entries in this table can be read without restriction.