Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwDomainTable

hwDomainTable

The hwDomainTable is a domain information table. You can use this table to configure basic attributes of a domain. The device provides two default domains, namely, default and default_admin. The default domains can be modified but cannot be deleted.

The index of this table is hwDomainName.

OID

Object

Syntax

Maximum Access

Description

Status

1.3.6.1.4.1.2011.5.2.1.4.1.1

hwDomainName

DisplayString

read-only

This object indicates the domain name. The value is a string of 1 to 64 characters. No asterisk (*), question mark (?) and quotation mark (") are contained. The character string is case insensitive.

current

1.3.6.1.4.1.2011.5.2.1.4.1.2

hwDomainAuthenSchemeName

DisplayString

read-create

This object indicates the name of the authentication scheme used by the domain. The value is a string of 1 to 32 characters. The default authentication scheme of domains is default.

current

1.3.6.1.4.1.2011.5.2.1.4.1.3

hwDomainAcctSchemeName

DisplayString

read-create

This object indicates the name of the accounting scheme used by the domain. The value is a string of 1 to 32 characters. The default accounting scheme of domains is default.

current

1.3.6.1.4.1.2011.5.2.1.4.1.4

hwDomainRadiusGroupName

DisplayString

read-create

This object indicates the name of the RADIUS server group used by the domain. The value is a string of 1 to 32 characters. The RADIUS group must already exist.

current

1.3.6.1.4.1.2011.5.2.1.4.1.11

hwDomainRowStatus

RowStatus

read-create

This object indicates the row status, which can be created or deleted.

current

1.3.6.1.4.1.2011.5.2.1.4.1.13

hwDomainServiceSchemeName

DisplayString

read-create

This object indicates the name of the service scheme used by the domain. The value is a string of 1 to 32 characters. The service scheme must already exist.

current

1.3.6.1.4.1.2011.5.2.1.4.1.16

hwDomainForcePushUrl

DisplayString

read-create

Indicates the forcibly pushed URL in domain.

current

1.3.6.1.4.1.2011.5.2.1.4.1.17

hwDomainForcePushUrlTemplate

DisplayString

read-create

Indicates the name of the forcibly pushed URL template in domain.

current

1.3.6.1.4.1.2011.5.2.1.4.1.18

hwStateBlockFirstTimeRangeName

DisplayString

read-create

Indicates the first blocking time segment in domain.

NOTE:
  • If the value of hwStateBlockFirstTimeRangeName is --, the hwStateBlockFirstTimeRangeName, hwStateBlockSecondTimeRangeName, hwStateBlockThirdTimeRangeName, and hwStateBlockForthTimeRangeName objects are deleted.
  • If the value of hwStateBlockFirstTimeRangeName is not --, the values of following three objects cannot be --.

current

1.3.6.1.4.1.2011.5.2.1.4.1.19

hwStateBlockSecondTimeRangeName

DisplayString

read-create

Indicates the second blocking time segment in domain.

NOTE:
To configure this object, configure the hwStateBlockFirstTimeRangeName object first.

current

1.3.6.1.4.1.2011.5.2.1.4.1.20

hwStateBlockThirdTimeRangeName

DisplayString

read-create

Indicates the third blocking time segment in domain.

NOTE:
To configure this object, configure the hwStateBlockFirstTimeRangeName and hwStateBlockSecondTimeRangeName objects first.

current

1.3.6.1.4.1.2011.5.2.1.4.1.21

hwStateBlockForthTimeRangeName

DisplayString

read-create

Indicates the fourth blocking time segment in domain.

NOTE:
To configure this object, configure the hwStateBlockFirstTimeRangeName, hwStateBlockSecondTimeRangeName, and hwStateBlockThirdTimeRangeName objects first.

current

Creation Restriction

None.

Modification Restriction

The modification restrictions are as follows:

  • The authentication scheme specified for a domain must exist; otherwise, the configuration fails.

  • The accounting scheme specified for a domain must exist; otherwise, the configuration fails.

  • The RADIUS server group specified for level-1 authentication and accounting in a domain must exist; otherwise, the configuration fails.

  • The service scheme specified for a domain must exist; otherwise, the configuration fails.

Deletion Restriction

A domain cannot be deleted in the following situations:

  • The domain contains users.

  • The domain is referenced by the service configured on a sub-interface.