S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwMplsInterfaceTable

hwMplsInterfaceTable

This table is used to configure or delete the MPLS capability on the interface.

The index of this table is hwMplsInterfaceIndex.

OID

Object Name

Syntax

Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.182.1.51.1.1

hwMplsInterfaceIndex

InterfaceIndex

Not-accessible

This object indicates the interface index. You can get the correct interface index based on the ifIndex of ifTable.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.182.1.51.1.11

hwMplsMtu

Integer32

Read-create

This object indicates the MPLS MTU of an interface. If the value of the MPLS MTU is set as 0, it indicates that the MPLS MTU is deleted.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.182.1.51.1.51

hwMplsInterfaceRowStatus

RowStatus

Read-create

This object indicates whether one entry is created or deleted in hwMplsInterfaceTable. The value of the object can be CreateAndGo and Destroy. When the value is set as CreateAndGo, and the entry is created, the status of the object is changed into active.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

You can enable the MPLS capability on the interface only after MPLS is enabled globally.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

None.