S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
dot1qLearningConstraintsTable

dot1qLearningConstraintsTable

This table provides information about learning constraints for shared and independent VLANs.

The indexes of this table are dot1qConstraintVlan and dot1qConstraintSet.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.2.1.17.7.1.4.8.1.1

dot1qConstraintVlan

VlanIndex

Not-accessible

This object indicates the index of this table, identifying the constrained VLAN.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.17.7.1.4.8.1.2

dot1qConstraintSet

Integer32(0..65535)

Not-accessible

This object indicates the index of this table, identifying the constraint setting of a VLAN.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.17.7.1.4.8.1.3

dot1qConstraintType

INTEGER

{

independent(1),

shared(2)

}

Read-create

The value of this object identifies the constraint type of a VLAN.

  • independent(1) indicates that the VLAN uses a filtration database independently from all other VLANs with the same setting.

  • shared(2) indicates that VLANs with the same setting share one filtration database.

Currently, the maximum access is read-only.

1.3.6.1.2.1.17.7.1.4.8.1.4

dot1qConstraintStatus

RowStatus

Read-create

This object indicates the row status.

Currently, the maximum access is read-only.

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction