No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
pingResultsTable

pingResultsTable

This table is used to save the test results. The index of this table is the index of the pingCtlTable. Each row of the pingCtlTable generates one row of the pingResultsTable only. When the test row is being tested, a test result is created correspondingly. The test-result parameter records the most updated test result only.

The indexes of this table are pingCtlOwnerIndex and pingCtlTestName.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.2.1.80.1.3.1.1

pingResultsOperStatus

INTEGER {

enabled(1),

disabled(2),

completed(3)

}

Read-only

Reflects the operational state of a pingCtlEntry.
  • enabled(1): The test is active.
  • disabled(2): The test has stopped.
  • completed(3): The test is completed

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.80.1.3.1.2

pingResultsIpTargetAddressType

InetAddressType

Read-only

This object indicates the type of address stored in the corresponding pingResultsIpTargetAddress object.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.80.1.3.1.3

pingResultsIpTargetAddress

InetAddress

Read-only

This object reports the IP address associated with a pingCtlTargetAddress value when the destination address is specified as a DNS name. The value of this object should be a zero-length octet string when a DNS name is not specified or when a specified DNS name fails to resolve.

The address type (InetAddressType) that relates to this object is specified by the corresponding value of pingResultsIpTargetAddressType.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.80.1.3.1.4

pingResultsMinRtt

Unsigned32

Read-only

The minimum ping round-trip-time (RTT) received. A value of 0 for this object implies that no RTT has been received.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.80.1.3.1.5

pingResultsMaxRtt

Unsigned32

Read-only

The maximum ping round-trip-time (RTT) received. A value of 0 for this object implies that no RTT has been received.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.80.1.3.1.6

pingResultsAverageRtt

Unsigned32

Read-only

The current average ping round-trip-time (RTT).

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.80.1.3.1.7

pingResultsProbeResponses

Gauge32

Read-only

Number of responses received for the corresponding pingCtlEntry and pingResultsEntry. The value of this object MUST be reported as 0 when no probe responses have been received.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.80.1.3.1.8

pingResultsSentProbes

Gauge32

Read-only

The value of this object reflects the number of probes sent for the corresponding pingCtlEntry and pingResultsEntry. The value of this object MUST be reported as 0 when no probes have been sent.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.80.1.3.1.9

pingResultsRttSumOfSquares

Unsigned32

Read-only

This object contains the sum of the squares for all ping responses received. Its purpose is to enable standard deviation calculation. The value of this object MUST be reported as 0 when no ping responses have been received.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.2.1.80.1.3.1.10

pingResultsLastGoodProbe

DateAndTime

Read-only

Date and time when the last response was received for a probe.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

This table cannot be set. Test results rows are automatically created when pingCtlTable carries out a test.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted. When a row of the pingCtlTable is deleted, the system would delete the corresponding test results automatically.

Access Restriction

The entries in this table can be read without restriction.

Translation
Download
Updated: 2019-03-29

Document ID: EDOC1000178122

Views: 734433

Downloads: 36

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next