Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwPortLoopDetectTable

hwPortLoopDetectTable

The index of this table is hwPortLoopDetectIfIndex.

OID

Object Name

Syntax

Maximum Access

Description

Access

1.3.6.1.4.1.2011.5.25.174.1.1.7.1.1

hwPortLoopDetectIfIndex

InterfaceIndex

Not-accessible

This object indicates the interface index.

current

1.3.6.1.4.1.2011.5.25.174.1.1.7.1.2

hwLPortLoopDetectIfName

OCTET STRING

Read-only

This object specifies the name of an interface. The maximum length must be less than or equal to 48 characters.

Current

1.3.6.1.4.1.2011.5.25.174.1.1.7.1.3

hwPortLoopDetectEnabled

EnabledStatus

Read-write

This object indicates the loop detection status on the interface. The options are as follows:

  • 1: enabled
  • 2: disabled

Current

1.3.6.1.4.1.2011.5.25.174.1.1.7.1.4

hwPortLoopDetectRecoveryTime

Integer32

Read-write

This object indicates the automatic recovery delay. The value ranges from 0 to 1000, in seconds.

The default value is three times the interval for sending detection packets, that is, 15s.

Current

1.3.6.1.4.1.2011.5.25.174.1.1.7.1.5

hwPortLoopDetectAction

INTEGER

Read-write

This object specifies the processing mode of an interface. The options are as follows:

  • 1: shutdown
  • 2: blocking
  • 3: trap
  • 4: noLearning
  • 5: quitvlan

The default value is 1, indicating that the interface is shutdown.

Current

1.3.6.1.4.1.2011.5.25.174.1.1.7.1.6

hwPortLoopDetectStatus

INTEGER

Read-only

This object indicates the interface status. The options are as follows:

  • 1: normal
  • 2: blocking
  • 3: shutdown
  • 4: trap
  • 5: noLearning
  • 6: quitvlan

Current

1.3.6.1.4.1.2011.5.25.174.1.1.7.1.8

hwPortLoopDetectVlanLow

OCTET STRING

Read-write

This object indicates the low VLAN ID. The value ranges from 1 to 2047.

Current

1.3.6.1.4.1.2011.5.25.174.1.1.7.1.9

hwPortLoopDetectVlanHigh

OCTET STRING

Read-write

This object indicates the high VLAN ID. The value ranges from 2048 to 4094.

Current

Creation Restriction

Entries can be created in this table without restriction.

Modification Restriction

When the automatic recovery delay is 0, the default value (15s) is used.

Deletion Restriction

The entries in this table can be deleted without restriction.

Access Restriction

None.

Translation