Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwAirScanProfileTable

hwAirScanProfileTable

This table is used to configure air scan intervals, duration, and scan channel sets.

The index of this table is hwAirScanProfileName.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.139.11.1.19.1.1

hwAirScanProfileName

OCTET STRING(1–35)

not-accessible

This object indicates the name of an air scan profile. It is the index of the table.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.19.1.2

hwAirScanPeriod

Unsigned32(60–100)

read-write

This object indicates the air scan period. The default value is 60, in milliseconds.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.19.1.3

hwAirScanInterval

Unsigned32(300–600000)

read-write

This object indicates the scan interval. The default value is 60000, in milliseconds.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.19.1.4

hwAirScanChannelSet

INTEGER{countryChannel(1),dcaChannel(2),workChannel(3)}

read-write

This object indicates the scan channel set. The default value is 1.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.139.11.1.19.1.8

hwAirScanSwitch

INTEGER{disable(1),enable(2)}

read-write

This object indicates whether air scan is enabled. The default value is 1.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

You can create entries in this table without restriction.

Modification Restriction

The entries in this table can be modified without restriction.

Deletion Restriction

The default profile cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.