S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwCBQoSPolicyCfgInfoTable

hwCBQoSPolicyCfgInfoTable

This table describes traffic policy configurations.

The index of this table is hwCBQoSPolicyIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.32.1.1.3.2.1.1

hwCBQoSPolicyIndex

Integer32

Read-only

This object indicates the traffic policy index. The value ranges from 0 to 256.

There is no default value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.32.1.1.3.2.1.2

hwCBQoSPolicyName

OCTET STRING

Read-create

This object indicates the name of a traffic policy. The value is an ASCII string of 1 to 64 characters without spaces.

There is no default value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.32.1.1.3.2.1.3

hwCBQoSPolicyClassCount

Integer32

Read-only

This object indicates the number of traffic classifiers bound to a traffic policy. The value ranges from 1 to 257.

Default value: 1.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.32.1.1.3.2.1.5

hwCBQoSPolicyRowStatus

RowStatus

Read-create

This object indicates the row status.
  • 1: active
  • 4: createandgo
  • 6: destroy

There is no default value.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

  • A maximum of 256 traffic policies can be created.
  • hwCBQoSPolicyIndex must be the same as the value of the single object hwCBQoSPolicyIndex.
  • The value of hwCBQoSPolicyName must be unique.
  • You can create entries in this table only when the row status is CreateAndGo, and values of both hwCBQoSPolicyIndex and hwCBQoSPolicyName are set.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

To delete a traffic policy, delete all the rows whose hwCBQoSIfApplyPolicyName values are hwCBQoSPolicyName from the hwCBQoSIfApplyPolicyTable.

Access Restriction

The entries in this table can be read without restriction.