S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwUSCConfigTable

hwUSCConfigTable

This table describes the interface configuration on a control device.

The index of this table is hwUSCPortIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.40.19.1.1.1

hwUSCPortIndex

Integer(32)

read-only

This object indicates the table index.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.40.19.1.1.2

hwUSCInterfaceName

Octet String

read-only

This object indicates the interface name. The value ranges from 1 to 64.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.40.19.1.1.3

hwAuthenControlPoint

INTEGER

read-write

This object indicates whether the interface is enabled as the control point.
  • 0: enabled
  • 1: disabled

The default value is disabled.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.40.19.1.1.4

hwUSCLinkDownOffline

Integer(32)

read-write

This object indicates the offline delay for users on an access device after the interface link is disconnected intermittently. The value is an integer that ranges from 0 to 65535, in seconds. The default value is 10.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.40.19.1.1.5

hwUSCControlDownOffline

Integer(32)

read-write

This object indicates the offline delay for users on an access device after the control tunnel is faulty. The value is an integer that ranges from 0 to 65535, in seconds. The default value is 0, indicating that the users on an access device immediately go offline after the control tunnel is faulty.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.40.19.1.1.6

hwUSCUserSyncInterval

Integer(32)

read-write

This object indicates the interval for synchronizing users and online users on an access device. The value is an integer that ranges from 60 to 3600, in seconds. The default value is 60.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.40.19.1.1.7

hwUSCUserSyncRetry

Integer(32)

read-write

This object indicates the maximum number of attempts for synchronizing users and online users on an access device. The value ranges from 5 to 300. The default value is 5.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

None

Modification Restriction

None

Deletion Restriction

None

Access Restriction

None

Translation