Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwKompellaVpnTable

hwKompellaVpnTable

This table is used to display information about the Kompella L2VPN configuration. You can create and delete a Kompella L2VPN by using this table. Currently, this table supports the GET operation, rather than the SET operation.

The index of this table is hwKompellaVpnName.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.119.2.1.1.1.1

hwKompellaVpnName

DisplayString (SIZE (1..31))

Not-accessible

This object indicates the VPN name.

The name is a case-sensitive string of 1 to 31 characters with no space.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.119.2.1.1.1.2

hwKompellaVpnVcType

HWL2VpnVcEncapsType

Read-create

This object indicates the encapsulation type of the Kompella VC. For details, see KompellaVpnVcType.

Currently, the maximum access is read-only.

1.3.6.1.4.1.2011.5.25.119.2.1.1.1.3

hwKompellaVpnRouteDistinguisher

DisplayString (SIZE (3..21))

Read-create

This object indicates the Route Distinguisher (RD) value of the VPN.

The format is ASN:nn or IP-address:nn.

If this object is not correctly configured, hwKompellaCeTable and hwKompellaVcTable cannot be created.

Currently, the maximum access is read-only.

1.3.6.1.4.1.2011.5.25.119.2.1.1.1.4

hwKompellaVpnCtrlWord

HWEnableValue

Read-create

The value of this object identifies the control word function is enabled. The object has the following values:
  • 1: true
  • 2: false

Currently, the maximum access is read-only.

1.3.6.1.4.1.2011.5.25.119.2.1.1.1.5

hwKompellaVpnMtu

Unsigned32(size(0|46..16352))

Read-create

The value of this object identifies the MTU value of the Kompella VC.

The value is a decimal integer that ranges from 46 to 16352. The default value is 1500.

Currently, the maximum access is read-only.

1.3.6.1.4.1.2011.5.25.119.2.1.1.1.51

hwKompellaVpnRowStatus

RowStatus

Read-create

This object indicates the row status of this table.

Deletion of a Kompella L2VPN causes deletion of hwKompellaCeTable and hwKompellaVcTable that are associated with this VPN.

Currently, the maximum access is read-only.

Creation Restriction

No entry in this table can be created.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restraint.

Translation
Download
Updated: 2019-03-29

Document ID: EDOC1000178122

Views: 766029

Downloads: 36

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next