S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwQinQSubIfDot1qTermTable

hwQinQSubIfDot1qTermTable

This table is used to create or delete the dot1q termination configuration.

The index of this table is hwQinQSubIfDot1qTermIfIndex.hwQinQSubIfDot1qTermVidStart.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.116.2.8.1.1

hwQinQSubIfDot1qTermIfIndex

InterfaceIndex

Not-accessible

This object indicates the index of the dot1q termination sub-interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.116.2.8.1.2

hwQinQSubIfDot1qTermVidStart

VlanId

Not-accessible

This object indicates the start VID of the CE VLANs permitted by the dot1q termination sub-interface. The value ranges from 1 to 4094.

Currently, the value range of 1 to 4094 is supported.

1.3.6.1.4.1.2011.5.25.116.2.8.1.3

hwQinQSubIfDot1qTermVidEnd

VlanId

Read-create

This object indicates the end VID of the CE VLANs permitted by the dot1q termination sub-interface.

Currently, the value range of 1 to 4094 is supported.

1.3.6.1.4.1.2011.5.25.116.2.8.1.5

hwQinQSubIfDot1qTermRowStatus

RowStatus

Read-create

This object indicates the row status.

  • 1: active
  • 2: notInService
  • 3: notReady
  • 4: createAndGo
  • 5: createAndWait
  • 6: destroy

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

  • The number of ranges of CE VLAN IDs for dot1q termination on a sub-interface cannot be greater than 16, and CE VLAN IDs cannot overlap.

For example, if the value of hwQinQSubIfDot1qTermVidStart is set to 500 and the value of hwQinQSubIfDot1qTermVidEnd is set to 600, the value of hwQinQSubIfDot1qTermVidStart cannot be set to 300 and the value of hwQinQSubIfDot1qTermVidEnd cannot be set to 600. This is because overlapping exists between 300 to 500.

  • A sub-interface can be enabled with one of the three functions, that is, dot1q, QinQ, and VLAN stacking.

For example, if hwQinQSubIfTermTable or hwQinQSubIfVlanStackingTable is created, hwQinQSubIfDot1qTermTable cannot be created.

  • The settings of hwQinQSubIfDot1qTermVidStart and hwQinQSubIfDot1qTermVidEnd cannot overlap the setting of hwQinQSubIfVlanStackingCE in hwQinQSubIfTermPEVlan or hwQinQSubIfVlanStackingTable.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

None.