No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwIfMonitorThresholdTable

hwIfMonitorThresholdTable

This table is used to query and configure alarm messages.

The index of this table is hwIfMonitorIndex.

OID

Object Name

Syntax

Maximum Access

Description

Access

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.1

hwIfMonitorIndex

InterfaceIndex

Not-accessible

This object indicates the interface index.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.2

hwIfMonitorCrcErrorStatistics

Counter64

Read-only

This object indicates the number of packets with CRC errors.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.3

hwIfMonitorCrcErrorThreshold

Integer32

Read-write

This object indicates the alarm threshold of CRC error packets. The value is an integer that ranges from 1 to 65535.

The default value is 3.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.4

hwIfMonitorCrcErrorInterval

Integer32

Read-write

This object indicates the interval at which the CRC error packet alarms are reported. The value is expressed in seconds.

The default value is 10.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.8

hwIfMonitorInputRate

Integer32

Read-only

This object indicates the inbound bandwidth usage.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.9

hwIfMonitorInputRateThreshold

Integer32

Read-write

This object indicates the alarm threshold of the inbound bandwidth usage. The value ranges from 1 to 100.

The default value is 80.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.10

hwIfMonitorOutputRate

Integer32

Read-only

This object indicates the outbound bandwidth usage.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.11

hwIfMonitorOutputRateThreshold

Integer32

Read-write

This object indicates the alarm threshold of the outbound bandwidth usage. The value ranges from 1 to 100.

The default value is 80.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

No entry can be created in this table.

Modification Restriction

If the specified interface is the outbound interface for Layer 2 forwarding, the interface must be a switched interface (Layer 2 interface).

Deletion Restriction

No entry in this table can be deleted.

Access Restriction

The entries in this table can be read without restriction.

Translation
Download
Updated: 2019-03-29

Document ID: EDOC1000178122

Views: 679509

Downloads: 34

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next