Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwDot3ahEfmEventLogTable

hwDot3ahEfmEventLogTable

This table is used to manage logs of events on the interfaces.

The indexes of this table are ifIndex and hwDot3ahEfmEventLogIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.1

hwDot3ahEfmEventLogIndex

Unsigned32

Not-accessible

This object indicates the single event in the log of any int type.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.2

hwDot3ahEfmEventLogTimestamp

TimeStamp

Read-only

This object indicates the time of storing the event in the log.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.3

hwDot3ahEfmEventLogOui

HWDot3Oui

Read-only

This object indicates the OUI of the event. The OUI of the 802.3ah standard event is 0x0180C2.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.4

hwDot3ahEfmEventLogType

Unsigned32

Read-only

This object indicates the type of the event recorded in the log.
  • 1: erroredSymbolEvent.

  • 2: erroredFrameEvent.

  • 3: erroredFramePeriodEvent.

  • 4: erroredFrameSecondsEvent.

  • 256: linkFault.

  • 257: dyingGaspEvent.

  • 258: criticalLinkEvent.

Currently, the erroredFramePeriodEvent is not supported.

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.5

hwDot3ahEfmEventLogLocation

INTEGER

{

local(1),

remote(2)

}

Read-only

This object indicates that the event is a local one or a remote one.1: the local event; 2: the remote event.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.6

hwDot3ahEfmEventLogWindowHi

Unsigned32

Read-only

This object indicates that if the event is a threshold-crossing one, the two values of unsigned32 are combined together to indicate the monitoring interval.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.7

hwDot3ahEfmEventLogWindowLo

Unsigned32

Read-only

This object indicates that if the event is a threshold-crossing one, the two values of unsigned32 are combined together to indicate the monitoring interval.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.8

hwDot3ahEfmEventLogThresholdHi

Unsigned32

Read-only

This object indicates that if the event is a threshold-crossing one, the two values of unsigned32 are combined together to indicate the threshold value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.9

hwDot3ahEfmEventLogThresholdLo

Unsigned32

Read-only

This object indicates that if the event is a threshold-crossing one, the two values of unsigned32 are combined together to indicate the threshold value.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.10

hwDot3ahEfmEventLogValue

CounterBasedGauge64

Read-only

This object indicates the number of times that the threshold-crossing events occur (the accurate value that exceeds the threshold).

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.11

hwDot3ahEfmEventLogRunningTotal

CounterBasedGauge64

Read-only

This object indicates the number of times that the events occur.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.12

hwDot3ahEfmEventLogEventTotal

Unsigned32

Read-only

This object indicates the number of times that the events cause notification.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

None.

Modification Restriction

None.

Deletion Restriction

None.

Access Restriction

None.

Translation