Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwRrppRingTable

hwRrppRingTable

This table describes the information about the attributes of the RRPP ring.

The indexes of this table are hwRrppDomainID and hwRrppRingID.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.113.2.2.1.1

hwRrppRingID

INTEGER (1..64)

Not-accessible

The value of this object identifies the ID of an RRPP ring. Each RRPP ring maps a physical Ethernet network topology in the shape of a ring. Each RRPP ring is a part of the RRPP domain to which it belongs.

Actually, RRPP takes effect on the RRPP ring. The ring in the RRPP domain can be classified into the major ring and the sub-ring. The major ring and the sub-ring are distinguished by their configured levels. The level of the major ring is set to 0; the level of the sub-ring is set to 1.

The value ranges from 1 to 64.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.2.1.2

hwRrppRingEnableStatus

EnabledStatus

Read-create

The value of this object identifies whether the ring is enabled.

The values are as follows:

  • 1: enable
  • 2: disable

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.2.1.3

hwRrppRingActive

INTEGER

{

active(1),

inactive(2)

}

Read-only

The value of this object identifies whether the ring is activated. The values are as follows:

  • 1: active
  • 2: inactive

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.2.1.4

hwRrppRingState

INTEGER

{

unknown(1),

health(2),

fault(3),

complete(4),

failed(5),

linkup(6),

linkdown(7),

preforwarding(8),

linkupnotify(9),

linkdownnotify(10),

preforwardnotify(11)

}

Read-only

The value of this object identifies the status of the ring.

NOTE:

The values 2 and 3 are used only in traps.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.2.1.5

hwRrppRingNodeMode

INTEGER

{

master(1),

transit(2),

edge(3),

assistantEdge(4)

}

Read-create

The value of this object identifies the mode of the RRPP node. The values are as follows:

  • 1: master
  • 2: transit
  • 3: edge
  • 4: assistantEdge

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.2.1.6

hwRrppRingPrimaryPort

InterfaceIndex

Read-create

This object indicates the index of the main interface. When the node is an edge node or an assistant edge node, it indicates the index of the public interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.2.1.7

hwRrppRingSecondaryPort

InterfaceIndex

Read-create

This object indicates the index of the secondary interface. When the node is an edge node or an assistant edge node, it indicates the index of the edge interface.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.2.1.8

hwRrppRingLevel

Integer

{

majorRing(0),

subRing(1)

}

Read-create

The value of this object identifies the level of the ring.

The values are as follows:

  • 0: major ring
  • 1: sub-ring

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.2.1.9

hwRrppRingRowStatus

RowStatus

Read-create

The object indicates the row status of this table.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.113.2.2.1.10

hwRrppRingResetStatistics

Integer

Read-create

The object indicates clearing the statistics of packets received and sent on the current ring.
  • cleared(1)

  • unused(2)

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

The switch on the major ring of the RRPP domain can serve as a master node or a transit node. The switch on the sub-ring can serve as a master node, a transit node, an edge node, or an assistant edge node.

The sub-ring can be created on the following conditions:

  • When the node is an edge node or an assistant edge node, the public interface of the sub-ring is the interface shared with the major ring.

Modification Restriction

The switch on the major ring of the RRPP domain can serve as a master node or a transit node. The switch on the sub-ring can serve as a master node, a transit node, an edge node, or an assistant edge node.

Deletion Restriction

When deleting a ring, make sure that the ring is disabled; otherwise, the ring cannot be deleted.

Before you delete the major ring, make sure that the sub-ring is deleted. Otherwise, the major ring cannot be deleted.

Access Restriction

The entries in this table can be read without restraint.