S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
HUAWEI-CLOCK-MIB

HUAWEI-CLOCK-MIB

Function Overview

HUAWEI-CLOCK-MIB is a private MIB defined by Huawei. It is used to manage and query the clock. This MIB can be used to configure and query attributes of the clock reference source.

Root directory:

iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).huawei(2011).huaweiMgmt(5).hwDatacomm(25).hwClockMIB(186)

NOTE:

If some objects of this MIB have different attribute values in the MIB file and this document, the values listed in this document apply.

Relationships Between Tables

None.

Description of Single Objects

hwClockSourceEthClkEnable

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.1.1

hwClockSourceEthClkEnable

EnabledStatus

Read-write

This object indicates that the Ethernet clock is globally enabled.

This object is currently read-only.

hwClockSourceSsmUnknown

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.1.2

hwClockSourceSsmUnknown

INTEGER

Read-write

This object indicates the quality level mapped to the QL_UNKNOWN value. The value can be:
  • prc(2)
  • ssua(4)
  • ssub(8)
  • sec(11)
  • dnu(15)

The default value is dnu(15).

The implemented data type is Enumeration.

hwClockSourceSysClkWorkMode

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.1.3

hwClockSourceSysClkWorkMode

INTEGER

Read-only

This object indicates the running mode of the clock source. The value can be:
  • trace(1)
  • hold(2)
  • freeoscillate(3)

The implemented data type is Enumeration and the maximum access is read-only.

hwClockSourceSsmControl

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.1.5

hwClockSourceSsmControl

INTEGER

read-write

This object indicates the selection mode of the clock source. The value can be:
  • on(1)
  • off(2)
  • extend(3)

The implemented data type is Enumeration.

hwClockSourceHoldMode

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.1.6

hwClockSourceHoldMode

INTEGER

read-write

This object indicates the hold mode of the clock source.

The value can be:

  • hold24Hours(1)
  • holdForever(2)

This object is implemented as defined in the corresponding MIB files.

hwClockSourceFreqCheckEnable

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.1.7

hwClockSourceFreqCheckEnable

INTEGER

Read-write

This object indicates whether the frequency offset detection is enabled.

The implemented data type is Enumeration.

hwClockSourceFreqCheckLeftRange

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.1.8

hwClockSourceFreqCheckLeftRange

Integer32 min: 50 max: 1000

read-write

Indicates the range of the left frequency offset detection.

This object is implemented as defined in the corresponding MIB file.

hwClockSourceFreqCheckRightRange

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.1.9

hwClockSourceFreqCheckRightRange

Integer32 min: 50 max: 1000

read-write

Indicates the range of the right frequency offset detection.

This object is implemented as defined in the corresponding MIB file.

hwClockSourceRetrieveMode

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.1.10

hwClockSourceRetrieveMode

INTEGER

Read-write

This object indicates the recovery mode of the clock source. The value can be:
  • retrieve(1)
  • noRetrieve(2)

The implemented data type is Enumeration.

hwClockTimeUsedSource

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.1.11

hwClockTimeUsedSource

INTEGER

Read-write

This object indicates the clock source type. The value can be:
  • srcDclsTimeBit0(1)
  • srcDclsTimeBit1(2)
  • src1ppsTodBit0(3)
  • src1ppsTodBit1(4)
  • srcPtp(5)
  • srcFreeRun(6)

The implemented data type is Enumeration, and the values are read-only.

hwClockExtTimeInputType

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.1.12

hwClockExtTimeInputType

INTEGER

read-write

This object indicates the clock input type. The value can be:
  • typeDclsTime(1)
  • type1ppsTodRs232(2)
  • type1ppsTodGps(3)
  • typeNone(4)

The implemented data type is Enumeration, and the values are read-only.

hwClockExtTimeOutputType

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.1.13

hwClockExtTimeOutputType

INTEGER

Read-write

This object indicates the clock output type.

The implemented data type is Enumeration.

Description of MIB Tables

hwClockSourceSelTable

This table is used to set the parameters for selecting a clock source.

The indexes of this table are hwClockSourceSelChassisIndex and hwClockSourceSelType.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.2.1.1

hwClockSourceSelChassisIndex

INTEGER

not-accessible

This object indicates the chassis ID.

Synchronous Ethernet clock is not supported in a stack system, so the chassis ID is always 0.

1.3.6.1.4.1.2011.5.25.186.1.2.1.2

hwClockSourceSelType

Integer32

not-accessible

This object indicates the clock source selection type:
  • 1: The system clock is selected as the clock source.
  • 2: The BITS0 clock is selected as the clock source.
  • 3: The BITS1 clock is selected as the clock source.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.2.1.3

hwClockSourceSelMode

INTEGER

Read-create

This object indicates the clock source selection mode:
  • 1: auto
  • 2: manual
  • 3: force

The maximum access to this object is read-only.

1.3.6.1.4.1.2011.5.25.186.1.2.1.4

hwClockSourceSelSourceId

Integer32

Read-create

This object indicates the ID of a clock source.

The maximum access to this object is read-only.

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table can be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.

hwClockSourceCfgTable

This table is used to set parameters for a clock source.

The indexes of this table are hwClockCfgChassisIndex and hwClockCfgSourceIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.3.1.1

hwClockCfgChassisIndex

INTEGER

not-accessible

This object indicates the chassis ID.

Synchronous Ethernet clock is not supported in a stack system, so the chassis ID is always 0.

1.3.6.1.4.1.2011.5.25.186.1.3.1.2

hwClockCfgSourceIndex

Integer32

not-accessible

Indicates the clock source number.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.3.1.3

hwClockCfgSourceId

Integer32

Read-only

This object indicates the ID of a clock source.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.3.1.4

hwClockCfgSourceDescr

OctetString

Read-only

This object indicates the name of the clock source.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.3.1.5

hwClockCfgWtrTime

Integer32 min

Read-write This object indicates the wait to restore (WTR) time of the clock source.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.3.1.6

hwClockCfgBadDetect EnabledStatus

Read-write

This object indicates whether the frequency offset detection is enabled.

The implemented access right is read-only.

1.3.6.1.4.1.2011.5.25.186.1.3.1.7

hwClockCfgSystemPriority Integer32 Read-write This object indicates the priority of the system clock.

The value -1 indicates that the priority value is not supported. This value is not configurable.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.3.1.8

hwClockCfgBits0Priority Integer32 Read-write This object indicates the priority of the BITS0 clock source.

The value -1 indicates that the priority value is not supported. This value is not configurable.

The value ranges from 5 to 9 for BITS clock sources. If the priority is set to other values, the value of this object is displayed as -1.

1.3.6.1.4.1.2011.5.25.186.1.3.1.9

hwClockCfgBits1Priority Integer32 Read-write This object indicates the priority of the BITS1 clock source.

The value -1 indicates that the priority value is not supported. This value is not configurable.

The value ranges from 5 to 9 for BITS clock sources. If the priority is set to other values, the value of this object is displayed as -1.

1.3.6.1.4.1.2011.5.25.186.1.3.1.10

hwClockCfgSystemLockOut Integer32 Read-write This object indicates whether the clock source of the system clock is locked.

The value -1 indicates that clock source locking is not supported.

The local clock source and 19.44 MHz clock source cannot be locked. Other clock sources can be locked only after they have priority values configured.

1.3.6.1.4.1.2011.5.25.186.1.3.1.11

hwClockCfgBits0LockOut Integer32 Read-write This object indicates whether the clock source of BITS0 is locked.

The value -1 indicates that clock source locking is not supported.

The value ranges from 5 to 9 for BITS clocks. Other clock sources can be locked only after they have priority values configured. If a clock source cannot be locked, the value of this object is displayed as -1.

1.3.6.1.4.1.2011.5.25.186.1.3.1.12

hwClockCfgBits1LockOut Integer32 Read-write This object indicates whether the clock source of BITS1 is locked.

The value -1 indicates that clock source locking is not supported.

The value ranges from 5 to 9 for BITS clocks. Other clock sources can be locked only after they have priority values configured. If a clock source cannot be locked, the value of this object is displayed as -1.

1.3.6.1.4.1.2011.5.25.186.1.3.1.13

hwClockCfgSourceSsm Integer32 Read-write This object indicates the SSM quality level of the clock source. The value can be:
  • ssmPrc(1)
  • ssmSsut(2)
  • ssmSsul(3)
  • ssmSec(4)
  • ssmDnu(5)
  • ssmUnknown(6)

The SSM quality level cannot be set to ssmUnknown(6).

1.3.6.1.4.1.2011.5.25.186.1.3.1.14

hwClockCfgSourceSsmSetMode Enumeration Read-write This object indicates the mode for setting the SSM quality level of a clock source.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.3.1.17

hwClockCfgSourceState Enumeration

Read-write

This object indicates whether clock signals from the clock source are lost.

The implemented access right is read-only.

1.3.6.1.4.1.2011.5.25.186.1.3.1.18

hwClockCfgSsmThreshold Enumeration

Read-only

This object indicates the threshold of the SSM quality level of the clock source.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.3.1.19

hwClockCfgSourceS1Id Integer32

Read-only

This object indicates the S1 byte of the clock source.

This object is not supported in this version.

1.3.6.1.4.1.2011.5.25.186.1.3.1.20

hwClockCfgFreqCheckResult Integer32 Read-write This object indicates the result of the frequency offset detection.

This object is currently read-only.

1.3.6.1.4.1.2011.5.25.186.1.3.1.21

hwClockCfgHoldOffTime Integer32 Read-write This object indicates the hold-off time of a clock source.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

No entry can be created in this table.

Modification Restriction

None.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.

hwClockBitsCfgTable

This table is used to configure parameters for a BITS clock.

The indexes of this table are hwClockBitsCfgChassisIndex and hwClockBitsCfgBitsIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.4.1.1

hwClockBitsCfgChassisIndex

INTEGER

not-accessible

This object indicates the chassis ID.

Synchronous Ethernet clock is not supported in a stack system, so the chassis ID is always 0.

1.3.6.1.4.1.2011.5.25.186.1.4.1.2

hwClockBitsCfgBitsIndex

Integer32

not-accessible

BITS clock source type:
  • 1: BITS0 clock
  • 2: BITS1 clock

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.4.1.3

hwClockBitsCfgName

OCTET STRING

Read-only

This object indicates that the name of a clock is used as an index, for example, BITS0 and BITS1.

ATN devices do not support BIT32.

1.3.6.1.4.1.2011.5.25.186.1.4.1.4

hwClockBitsCfgBitsPortType

Enumeration

Read-only

This object indicates the type of the BITS interface:

  • portRJ45 (1)

  • portSMB (2)

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.4.1.5

hwClockBitsCfgBitsType

Enumeration

Read-write

This object indicates the type of the BITS clock:

  • type2Mbps(0)
  • type2Mhz(1)
  • typeDclsTime(2)
  • type1ppsTod(3)
  • none(4)
  • type1544Mbps(5)

The BITS clock type cannot be set to none(4).

1.3.6.1.4.1.2011.5.25.186.1.4.1.6

hwClockBitsCfgDirection

Enumeration

Read-write

This object indicates the direction of the BITS clock:

  • in(1)
  • out(2)
  • inAndOut(3)
  • none(4)
NOTE:

If the type of the BITS clock is 2 Mbps, 2 MHz, or 1.544 Mbps, the direction cannot be set to in(1) or out(2).

The direction of the BITS clock cannot be set to inAndOut(3) or none(4).

1.3.6.1.4.1.2011.5.25.186.1.4.1.7

hwClockBitsCfgRecvSaBit

Enumeration

Read-write

This object indicates the sa timeslot that identifies the SSM level in the bytes received by the BITS clock.

  • sa4(4)
  • sa5(5)
  • sa6(6)
  • sa7(7)
  • sa8(8)

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.4.1.8

hwClockBitsCfgSendSaBit

Enumeration

Read-write

This object indicates the sa timeslot that identifies the SSM level in the bytes sent by the BITS clock.

  • sa4(4)
  • sa5(5)
  • sa6(6)
  • sa7(7)
  • sa8(8)

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.4.1.9

hwClockBitsCfgForceOutS1

Integer32

Read-write

The value of this object identifies the S1 byte value forcibly sent from the BITS interface.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.4.1.10

hwClockBitsCfgSaBit

Enumeration

Read-write

This object indicates the sa timeslot that identifies the SSM level of the BITS clock.

  • sa4(4)
  • sa5(5)
  • sa6(6)
  • sa7(7)
  • sa8(8)

This object is not supported in this version.

1.3.6.1.4.1.2011.5.25.186.1.4.1.14

hwClockBitsCfgSourceId

Integer32

Read-only

The value of this object identifies the ID of the BITS clock source.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.4.1.15

hwClockBitsCfgTodSignal

Enumeration

Read-write

This object indicates the TOD format of the BITS clock.

This object is not supported in this version.

1.3.6.1.4.1.2011.5.25.186.1.4.1.16

hwClockBitsCfgFrameFormat

Enumeration

Read-write

This object indicates the code type and frame format of the BITS clock.

This object is not supported in this version.

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table can be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.

hwClockPortCfgTable

This table is used to set parameters for interfaces of a clock node.

The index of this table is hwClockPortCfgIfIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.186.1.5.1.1

hwClockPortCfgIfIndex

Integer32

not-accessible

This object indicates an interface index.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.5.1.2

hwClockPortCfgLeftFramePri

Integer32

read-write

This object indicates the clock interface range on the left side of the frame.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.5.1.3

hwClockPortCfgRightFramePri

Integer32

read-write

This object indicates the clock interface range on the right side of the frame.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.5.25.186.1.5.1.4

hwClockPortCfgForceOutS1

Integer32

read-write This object indicates the S1 byte.

The value -1 forcibly cancels the S1 byte configuration. This value is returned when the S1 byte is not configured.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table can be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.

Unsupported Objects

The functions corresponding to the following objects are not supported on the device. Do not use these MIB objects to maintain the device.

Table 26-1  List of unsupported objects

Object ID

Object Name

Table

1.3.6.1.4.1.2011.5.25.186.1.4.1.11

hwClockBitsCfgInputMode

hwClockBitsCfgTable

1.3.6.1.4.1.2011.5.25.186.1.4.1.12

hwClockBitsCfgOutputMode

hwClockBitsCfgTable

1.3.6.1.4.1.2011.5.25.186.1.4.1.13

hwClockBitsCfgInvalidCond

hwClockBitsCfgTable