Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwAclNumGroupTable

hwAclNumGroupTable

This table is used to configure information on ACL rule groups, including the ACL configuration order, step length, and description.

The index of this table is hwAclNumGroupAclNum.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.1.1.2.1.1

hwAclNumGroupAclNum

Integer32 (2000..2999 | 3000..3999 | 4000..4999 | 5000..5999 | 6000..9999)

Read-only

This object is the index of this table. Its value identifies the number of a rule group.

The value range varies with the type of ACLs:
  • Basic ACL: 2000 to 2999
  • Advanced ACL: 3000 to 3999
  • Layer 2 ACL: 4000 to 4999
  • User-defined ACL: 5000 to 5999
  • User ACL: 6000 to 9999

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.1.1.2.1.2

hwAclNumGroupMatchOrder

Integer32 { config(1), auto(2) }

Read-create

The value of this object identifies the matching order of a rule group.

The value can be:

  • config(1): indicates that ACL rules are matched following configuration sequences.
  • auto(2): indicates that ACL rules are matched following the depth first principle.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.1.1.2.1.3

hwAclNumGroupSubitemNum

Counter32

Read-only

The value of this object identifies the number of rules in a rule group.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.1.1.2.1.4

hwAclNumGroupStep

Integer32

Read-create

The value of this object identifies ACL steps.

If you do not specify the rule ID when creating a rule, a rule ID is automatically generated based on the ACL step.

The value of the ACL step ranges from 1 to 20. The default value is 5.

The rule ID automatically generated by the system begins with the step value so that a new rule can be inserted in front of the first rule. For instance, if the step value is 5, the rule ID begins with 5; if the step value is 2, the rule ID begins with 2.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.1.1.2.1.5

hwAclNumGroupDescription

OCTET STRING (SIZE (0..127))

Read-create

This object indicates the description of a rule group.

The value cannot be larger than 127.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.1.1.2.1.7

hwAclNumGroupRowStatus

RowStatus

Read-create

This object indicates the status of rows.

Currently, createAndGo, active, and destroy are implemented.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.1.1.2.1.8

hwAclNumGroupAclName

OCTET STRING (SIZE (1..64))

Read-create

The name of an ACL. It is a string of 1 to 64 case-sensitive characters without spaces. The name should start with a letter and can contain numbers, hyphens (-), or underlines (_).

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.1.1.2.1.9

hwAclNumGroupAclType

INTEGER

Read-create

The name of an ACL group, the value can be:

  • basic(1)
  • advanced(2)
  • link(3)
  • user(4)
  • ucl(8)

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

hwAclNumGroupCountClear is effective only when the rule group is counted. In addition, it is effective only at the time you perform the Set operation to this object. You need to specify the row status CreateAndGo of hwAclNumGroupRowStatus.

hwAclNumGroupAclName is effective only when the rule group is from 2000 to 9999.

Modification Restriction

If the rule group with the specified index contains rules, hwAclNumGroupMatchOrder cannot be modified.

hwAclNumGroupAclName object cannot be modified once a rule is created.

Deletion Restriction

There is no restriction when you delete the entries in this table. You only need to specify the primary index and row status destroy.

Access Restriction

The entries in this table can be read without restraint. hwAclNumGroupCountClear is effective only at the time you perform the Set operation to this object; therefore, the value of this object that you have read is of no actual meaning.