S12700 V200R011C10 MIB Reference

This document provides the function overview, relationships between tables, description of single objects, description of MIB tables, and description of alarm objects.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
hwBfdSlotTable

hwBfdSlotTable

This table is used to contain the statistics of the BFD sessions on the current board. The statistics include the number of sessions reserved for the one-hop sessions, number of one-hop sessions, and the total number of sessions.

The index of this table is hwBfdSlotID.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.5.25.38.2.5.1.1

hwBfdSlotID

Unsigned32 (0..31)

Not-accessible

The value of the object identifies the slot ID of the interface board.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.38.2.5.1.2

hwBfdSlotReserveOneHopSessNum

Unsigned32 (0..512)

Read-create

The value of the object identifies the number of one-hop sessions on the interface board.

The value ranges from 0 to 512.

By default, the value is 0.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.38.2.5.1.3

HwBfdSlotOneHopSessNum

Unsigned32 (0..512)

Read-only

The value of the object identifies the number of one-hop BFD sessions on the interface board.

The value ranges from 0 to 512.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.38.2.5.1.4

HwBfdSlotCurrentSessNum

Unsigned32 (0..512)

Read-only

The value of the object identifies the number of BFD sessions on the interface board.

The value ranges from 0 to 512.

This object is implemented as defined in the corresponding MIB files.

1.3.6.1.4.1.2011.5.25.38.2.5.1.5

hwBfdSlotRowStatus

RowStatus

Read-create

The value of the object identifies the row status.

This object is implemented as defined in the corresponding MIB files.

Creation Restriction

  • Restriction on resource reservation

    The number of reserved sessions must be within the range of one to the maximum number of sessions that the PAF permits to establish on the interface board.

  • Restriction on creating the resource reservation

    To create the reserved one-hop sessions on the board, you must set hwBfdSlotID and hwBfdSlotReserve1hopSessNum, and set hwBfdSlotRowStatus to 4.

Modification Restriction

hwBfdSlotReserve1hopSessNum can be modified, but not hwBfdSlotID.

Deletion Restriction

When the entry is deleted on a specified board, hwBfdSlotReserveOneHopSessNum is reset.

Access Restriction

The entries in this table can be read without restriction.