No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - Device Management

S1720, S2700, S5700, and S6720 V200R011C10

This document describes the principles and configurations of the Device Management features, and provides configuration examples of these features.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Temperature Thresholds for Fan Speed Adjustment

Configuring Temperature Thresholds for Fan Speed Adjustment

Context

The device uses fixed temperature thresholds to increase and decrease the fan speed by default. The fan speed increases when the device temperature exceeds the upper threshold and decreases when the device temperature falls below the lower threshold. If you want to keep the device working at a lower temperature, you can set lower fixed temperature thresholds.

Procedure

  1. (Optional) Run display fan speed-adjust threshold minus

    The default temperature thresholds and the adjusted thresholds are displayed

  2. Run system-view

    The system view is displayed.

  3. Run set fan speed-adjust threshold minus threshold-value [ slot slot-id ]

    The temperature thresholds for fan speed adjustment are specified.

    The new thresholds are the default temperature thresholds minus threshold-value. After this command is executed, both the threshold for increasing the fan speed and the threshold for lowering the fan speed are reduced.

    NOTE:

    The following switches do not support this command:

    • S1720GW series
    • S1720GW-E series
    • S1720GWR series: S1720-28GWR-4P, S1720-28GWR-4X, and S1720-28GWR-PWR-4TP
    • S1720GWR-E series: S1720-28GWR-4P-E, S1720-28GWR-4X-E, and S1720-28GWR-PWR-4TP-E
    • S1720GFR series
    • S2720EI series: S2720-12TP-EI, S2720-12TP-PWR-EI, S2720-28TP-EI, S2720-28TP-PWR-EI-L
    • S2750EI series: S2750-28TP-EI-AC and S2751-28TP-PWR-EI-AC
    • S5700LI series: S5700-28TP-LI-AC, S5700-28P-LI-AC, S5700-28P-LI-DC, S5700-10P-LI-AC, and S5700-10P-PWR-LI-AC
    • S5700S-LI series: S5700S-28P-LI-AC
    • S5710-X-LI series: S5710-28X-LI-AC
    • S5720LI series: S5720-12TP-LI-AC, S5720-12TP-PWR-LI-AC, S5720-28P-LI-AC, S5720-28TP-LI-AC, S5720-28TP-PWR-LI-AC, S5720-28X-LI-AC, S5720-28X-LI-DC, and S5720-16X-PWH-LI-AC
    • S5720S-LI series: S5720S-12TP-LI-AC, S5720S-12TP-PWR-LI-AC, S5720S-28P-LI-AC, S5720S-28TP-PWR-LI-AC, and S5720S-28X-LI-AC
    • S5720S-SI series: S5720S-28P-SI-AC, S5720S-28X-SI-AC, and S5720S-28X-SI-DC

    If one of the preceding switches can set up a stack with other switch models that support this command, this switch also supports this command so that this command can be executed and delivered in the stack.