Configuration Guide - Device Management

S1720, S2700, S5700, and S6720 V200R011C10

This document describes the principles and configurations of the Device Management features, and provides configuration examples of these features.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Licensing Requirements and Limitations for Energy-Saving Management

Licensing Requirements and Limitations for Energy-Saving Management

Involved Network Elements

Other network elements are not required.

Licensing Requirements

Energy-saving management configuration commands are available only after the S1720GW, S1720GWR, and S1720X have the license (WEB management to full management Electronic RTU License) loaded and activated and the switches are restarted. Energy-saving management configuration commands on other models are not under license control.

For details about how to apply for a license, see S Series Switch License Use Guide.

Version Requirements

Table 7-1  Applicable product models and versions

Product

Product Model

Software Version

S1700 S1720GFR

V200R006C10, V200R009C00, V200R010C00, V200R011C00, V200R011C10

S1720GW and S1720GWR

V200R010C00, V200R011C00, V200R011C10

S1720GW-E and S1720GWR-E

V200R010C00, V200R011C00, V200R011C10

S1720X and S1720X-E

V200R011C00, V200R011C10

Other S1700 models

Models that cannot be configured using commands. For details about features and versions, see S1700 Documentation Bookshelf.

S2700 S2700SI

V100R005C01, V100R006(C00&C01&C03&C05)

S2700EI

V100R005C01, V100R006(C00&C01&C03&C05)

S2710SI

V100R006(C03&C05)

S2720EI

V200R006C10, V200R009C00, V200R010C00, V200R011C10

S2750EI

V200R003C00, V200R005C00SPC300, V200R006C00, V200R007C00, V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10

S3700 S3700SI

V100R005C01, V100R006(C00&C01&C03&C05)

S3700EI

V100R005C01, V100R006(C00&C01&C03&C05)

S3700HI

V100R006C01, V200R001C00

S5700 S5700LI

V200R001C00, V200R002C00, V200R003(C00&C02&C10), V200R005C00SPC300, V200R006C00, V200R007C00, V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10

S5700S-LI

V200R001C00, V200R002C00, V200R003C00, V200R005C00SPC300, V200R006C00, V200R007C00, V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10

S5710-C-LI

V200R001C00

S5710-X-LI

V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10

S5720LI and S5720S-LI

V200R010C00, V200R011C00, V200R011C10

S5700SI

V100R005C01, V100R006C00, V200R001C00, V200R002C00, V200R003C00, V200R005C00

S5720SI and S5720S-SI

V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10

S5700EI

V100R005C01, V100R006(C00&C01), V200R001(C00&C01), V200R002C00, V200R003C00, V200R005(C00&C01&C02&C03)

S5710EI

V200R001C00, V200R002C00, V200R003C00, V200R005(C00&C02)

S5720EI

V200R007C00, V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10

S5700HI

V100R006C01, V200R001(C00&C01), V200R002C00, V200R003C00, V200R005(C00SPC500&C01&C02)

S5710HI

V200R003C00, V200R005(C00&C02&C03)

S5720HI

V200R006C00, V200R007(C00&C10), V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10

S5730SI

V200R011C10

S5730S-EI

V200R011C10

S6700 S6700EI

V100R006C00, V200R001(C00&C01), V200R002C00, V200R003C00, V200R005(C00&C01&C02)

S6720EI

V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10

S6720S-EI

V200R009C00, V200R010C00, V200R011C00, V200R011C10

S6720SI and S6720S-SI

V200R011C00, V200R011C10

S6720LI and S6720S-LI

V200R011C00, V200R011C10

NOTE:
To know details about software mappings, see Hardware Query Tool.

Feature Limitations

  • During device sleeping configuration, if you run the speed { 10 | 100 } command on any awakening port to set the port rate to 10 or 100 Mbit/s or run the loopback internal command on any awakening port to configure the loopback detection mode, the device cannot enter the sleeping state. To enable the device to enter the sleeping state, you need to configure the awakening port on which the speed { 10 | 100 } or loopback internal command has been configured as a non-awakening port or delete the speed { 10 | 100 } or loopback internal command configuration from the awakening port.

  • When the interval between the sleeping start time and end time is less than 10 minutes, the device will not enter the sleeping state.